bioRxivBioengineering
Engineering microscale systems for fully autonomous intracellular neural interfaces
Abstract
Conventional electrodes and associated positioning systems for intracellular recording from single neurons in vitro and in vivo are large and bulky, which has largely limited their scalability. Further, acquiring successful intracellular recordings is very tedious, requiring a high degree of skill not readily achieved in a typical laboratory. We report here a robotic, MEMS-based intracellular recording system to overcome the above limitations associated with form-factor, scalability and highly skilled and tedious manual operations required for intracellular recordings. This system combines three distinct technologies: 1) novel microscale, glass-polysilicon penetrating electrode for intracellular recording, 2) electrothermal microactuators for precise microscale movement of each electrode and 3) closed-loop control algorithm for autonomous positioning of electrode inside single neurons. Here, we demonstrate the novel, fully integrated system of glass-polysilicon microelectrode, microscale actuators and controller for autonomous intracellular recordings from single neurons in the abdominal ganglion of Aplysia Californica (n = 5 cells). Consistent resting potentials ( 60 mV) were recorded after each successful penetration attempt with the controller and microactuated glass-polysilicon microelectrodes. The success rate of penetration and quality of intracellular recordings achieved using electrothermal microactuators were comparable to that of conventional positioning systems. The MEMS-based system offers significant advantages: 1) reduction in overall size for potential use in behaving animals, 2) scalable approach to potentially realize multi-channel recordings and 3) a viable method to fully automate measurement of intracellular recordings. This system will be evaluated in vivo in future rodent studies.
- organism: Arabidopsis
- assay: electrophysiology
- research focus: cell type annotation
- approach: experimental assay
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- The \"sewing machine\" for minimally invasive neural recording
Timothy Hanson, Camilo A. Diaz-Botia, … Philip N. Sabes·bioRxiv·Mar 14, 2019
- Robotic Multi-Probe-Single-Actuator Inchworm Neural Microdrive
R. D. Smith, I. Kolb, … M. Barbic·bioRxiv·Oct 13, 2020
- CHIME: CMOS-hosted in-vivo microelectrodes for massively scalable neuronal recordings
Mihály Köllő, Romeo Rácz, … Andreas T. Schaefer·Frontiers in NeurosciencePeer-reviewed·Aug 11, 2020
- MEMS-Actuated Carbon Fiber Microelectrode for Neural Recording
R. S. Zoll, C. B. Schindler, … K. S. J. Pister·bioRxiv·Oct 12, 2018
- Carbon Fiber Electrodes for Intracellular Recording and Stimulation
Yu Huan, Jeffrey P. Gill, … Hillel J. Chiel·Journal of Neural EngineeringPeer-reviewed·Nov 26, 2021
- Fluidic Microactuation of Flexible Electrodes for Neural Recording
Flavia Vitale, Daniel G. Vercosa, … Jacob T. Robinson·Nano LettersPeer-reviewed·Dec 8, 2017