bioRxivNeurosciencePreprint
Scout-based Multi-Echo NAvigator (SMENA) for high temporal resolution motion and B0 estimation and correction: applications to multi-echo GRE and EPTI
Nan WangiD, Yi‐Cheng LiniD, Yannick BrackenieriD, Aizada NurdinovaiD, Zihan ZhouiD, Daniel AbrahamiD, Xiaozhi CaoiD, Congyu LiaoiD, Kawin SetsompopiD
Abstract
PurposeTo develop a data-driven technique, Scout-based Multi-Echo NAvigator (SMENA), for joint estimation of motion and B0 inhomogeneity ({delta}B0) at a temporal resolution of [~]200 ms with minimal additional scan time for gradient-echo acquisition. MethodsSMENA consists of two key acquisition components: SMENA-scout and SMENA-nav. SMENA-scout is a rapid 3D 4-mm multi-echo acquisition completed in less than 8 seconds, providing images with matched contrast and phase at multiple echo times. SMENA-nav captures signal variations induced by motion and{delta} B0 during the scan using compact multi-echo navigator trajectories (3.5 ms) embedded within each TR. Motion and{delta} B0 maps were jointly estimated every [~]200 ms through a model-based optimization framework relating SMENA-scout to SMENA-nav. The estimation accuracy and correction performance of SMENA were evaluated in simulations and in vivo using multi-echo GRE and GRE-EPTI acquisitions. Multiple prospective motion experiments, including large continuous movement and deep breathing, were investigated. ResultsIn both simulations and in vivo experiments, accurate motion and{delta} B0 estimation were achieved. Compared with motion-only estimation, joint estimation reduced rotation and translation errors. Joint motion and{delta} B0 correction resulted in substantial improvements in image quality, particularly at longer echo times, producing an NRMSE of 10.4% compared to 31.6% with motion-only correction. High-temporal-resolution tracking of motion and{delta} B0 enabled improved reconstruction quality in scenarios involving continuous motion and deep breathing. ConclusionSMENA enables high-temporal-resolution joint estimation of motion and{delta} B0 with minimal additional acquisition cost, providing a practical solution for motion- and{delta} B0-robust MRI.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Simultaneous pure T2 and varying T2'-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses
Fuyixue Wang, Zijing Dong, … Kawin Setsompop·NeuroImagePeer-reviewed·Oct 14, 2021
- Romer-EPTI: rotating-view motion-robust super-resolution EPTI for SNR-efficient distortion-free in-vivo mesoscale dMRI and microstructure imaging
Z. Dong, T. G. Reese, … F. Wang·bioRxiv·Jan 26, 2024
- Single-shot Echo Planar Time-resolved Imaging for multi-echo functional MRI and distortion-free diffusion imaging
Z. Dong, L. L. Wald, … F. Wang·bioRxiv·Jan 24, 2024
- Framewise multi-echo distortion correction for superior functional MRI
A. N. Van, D. F. Montez, … N. U. F. Dosenbach·bioRxiv·Nov 28, 2023
- MR-PET head motion correction based on co-registration of multi-contrast MR images
Zhaolin Chen, Francesco Sforazzini, … Gary F. Egan·Human Brain MappingPeer-reviewed·Jan 3, 2019
- Hi-Fi fMRI: High-resolution, fast-sampled and sub-second whole-brain functional MRI at 3T in humans
Benedetta Franceschiello, Simone Rumac, … Eleonora Fornari·bioRxiv·May 13, 2023