Romer-EPTI: rotating-view motion-robust super-resolution EPTI for SNR-efficient distortion-free in-vivo mesoscale dMRI and microstructure imaging
Z. Dong, T. G. Reese, H.-H. Lee, S. Y. Huang, J. R. Polimeni, L. L. Wald, F. Wang
Abstract
PurposeTo overcome the major challenges in dMRI acquisition, including low SNR, distortion/blurring, and motion vulnerability. MethodsA novel Romer-EPTI technique is developed to provide distortion-free dMRI with significant SNR gain, high motion-robustness, sharp spatial resolution, and simultaneous multi-TE imaging. It introduces a ROtating-view Motion-robust supEr-Resolution technique (Romer) combined with a distortion/blurring-free EPTI encoding. Romer enhances SNR by a simultaneous multi-thick-slice acquisition with rotating-view encoding, while providing high motion-robustness through a motion-aware super-resolution reconstruction, which also incorporates slice-profile and real-value diffusion, to resolve high-isotropic-resolution volumes. The in-plane encoding is performed using distortion/blurring-free EPTI, which further improves effective spatial resolution and motion robustness by preventing not only T2/T2*-blurring but also additional blurring resulting from combining encoded volumes with inconsistent geometries caused by dynamic distortions. Self-navigation was incorporated to enable efficient phase correction. Additional developments include strategies to address slab-boundary artifacts, achieve minimal TE for SNR gain at 7T, and achieve high robustness to strong phase variations at high b-values. ResultsUsing Romer-EPTI, we demonstrate distortion-free whole-brain mesoscale in-vivo dMRI at both 3T (500-m-iso) and 7T (485-m-iso) for the first time, with high SNR efficiency (e.g., [Formula]), and high image quality free from distortion and slab-boundary artifacts with minimal blurring. Motion experiments demonstrate Romer-EPTIs high motion-robustness and ability to recover sharp images in the presence of motion. Romer-EPTI also demonstrates significant SNR gain and robustness in high b-value (b=5000s/mm2) and time-dependent dMRI. ConclusionRomer-EPTI significantly improves SNR, motion-robustness, and image quality, providing a highly efficient acquisition for high-resolution dMRI and microstructure imaging.
02 /Specification & Classification
Click any tag to browse matching papers- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Single-shot Echo Planar Time-resolved Imaging for multi-echo functional MRI and distortion-free diffusion imaging
Z. Dong, L. L. Wald, … F. Wang·bioRxiv·Jan 24, 2024
- SNR-efficient distortion-free diffusion relaxometry imaging using ACcelerated Echo-train shifted EPTI (ACE-EPTI)
Z. Dong, F. Wang, … K. Setsompop·bioRxiv·Aug 27, 2021
- High-SNR Whole-Brain Mesoscale Diffusion MRI Using Rotating-View Acquisitions (ROVER-dMRI)
Qiang Liu, Yunqi Wang, … Yogesh Rathi A·bioRxiv·Oct 1, 2026
- Slice-direction geometric distortion evaluation and correction with reversed slice-select gradient acquisitions
Anna I. Blazejewska, Thomas Witzel, … Jon̈athan R. Polimeni·NeuroImagePeer-reviewed·Oct 23, 2022
- Spherical Echo-Planar Time-resolved Imaging (sEPTI) for rapid 3D quantitative T2* and Susceptibility imaging
Nan Wang, Congyu Liao, … Kawin Setsompop·Magnetic Resonance in MedicinePeer-reviewed·Sep 9, 2024
- Advancing High-Resolution 7T Diffusion MRI: Evaluating Phase-Encoding Correction Strategies for Distortion Correction from Basic to Four-Way Acquisitions
Kurt G. Schilling, Alexander J. S. Beckett, … An T. Vu·Magnetic Resonance ImagingPeer-reviewed·Apr 17, 2026