bioRxivNeurosciencePreprint
Motion tolerance in wearable OPM-MEG using dynamic field nulling
Mainak JasiD, Teppei MatsubaraiD, Steven M. StufflebeamiD, Padmavathi SundaramiD, Seppo P. AhlforsiD
- Citations
- 0
Abstract
Wearable magnetoencephalography (MEG) enabled by optically pumped magnetometers (OPMs) promises improved comfort and motion tolerance. This is particularly beneficial when measuring brain activity in children who cannot sit still for long periods of time. Compared to cryogenic MEG, wearable MEG allows larger head movements, but they result in artifacts due to uncompensated background fields and reduce source localization accuracy. Spatial filtering methods can partially compensate these motion-induced artifacts, but they are most effective when used in combination with background field nulling. This is because accurate spatial filtering relies on an accurate estimate of the sensor gain and orientation of its sensitive axis. Through simulations, we first deduce the target residual background field that is necessary for accurate dipole localization (< 1 cm) in the presence of head movements. Using our open-source printed circuit board (PCB) coils, we develop a method to dynamically null the background field. We demonstrate that our dynamic field nulling method allows improved localization of somatosensory evoked fields (SEFs) by maintaining the background field below the target residual fields established in the simulations. Our study highlights the importance of tracking both the background field and the head position relative to the background field for quality assurance in wearable MEG.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Magnetic Field Mapping and Correction for Moving OP-MEG
Stephanie Mellor, Tim M. Tierney, … Gareth Robert Barnes·IEEE Transactions on Biomedical EngineeringPeer-reviewed·Jul 29, 2021
- Wearable magnetoencephalography in an open environment
Fufu Zheng, Congcong Li, … Jia‐Hong Gao·bioRxiv·Jul 31, 2026
- Noise Reduction and Localization Accuracy in a Mobile Magnetoencephalography System
T. Bardouille, V. Smith, … N. Holmes·bioRxiv·Mar 20, 2024
- Using OPMs to measure neural activity in standing, mobile participants
Robert A. Seymour, Nicholas Alexander, … Eleanor A. Maguire·NeuroImagePeer-reviewed·Sep 21, 2021
- On-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers
Joonas Iivanainen, Rasmus Zetter, … Lauri T. Parkkonen·NeuroImagePeer-reviewed·Mar 15, 2019
- Using OPM-MEG in contrasting magnetic environments
Ryan M. Hill, Jasen Devasagayam, … Matthew J. Brookes·NeuroImagePeer-reviewed·Mar 9, 2022