IEEE Transactions on Biomedical EngineeringNeurosciencePeer-reviewed journal article
Magnetic Field Mapping and Correction for Moving OP-MEG
Stephanie MelloriD, Tim M. TierneyiD, George C. O’NeilliD, Nicholas AlexanderiD, Robert A. SeymouriD, Niall HolmesiD, José David LópeziD, Ryan M. HilliD, Elena BotoiD, Molly ReaiD, Gillian RobertsiD, James LeggettiD, Richard W BowtelliD, Matthew J. BrookesiD, Eleanor A. MaguireiD, Matthew C. WalkeriD, Gareth Robert BarnesiD
Abstract
BackgroundOptically pumped magnetometers (OPMs) have made moving, wearable magnetoencephalography (MEG) possible. The OPMs typically used for MEG require a low background magnetic field to operate, which is achieved using both passive and active magnetic shielding. However, the background magnetic field is never truly zero Tesla, and so the field at each of the OPMs changes as the participant moves. This leads to position and orientation dependent changes in the measurements, which manifest as low frequency artefacts in MEG data. ObjectiveWe modelled the spatial variation in the magnetic field and used the model to predict the movement artefact found in a dataset. MethodsWe demonstrate a method for modelling this field with a triaxial magnetometer, then showed that we can use the same technique to predict the movement artefact in a real OPM-based MEG (OP-MEG) dataset. ResultsUsing an 86-channel OP-MEG system, we found that this modelling method maximally reduced the power spectral density of the data by 26.2 {+/-} 0.6 dB at 0 Hz, when applied over 5 s non-overlapping windows. ConclusionThe magnetic field inside our state-of-the art magnetically shielded room can be well described by low-order spherical harmonic functions. We achieved a large reduction in movement noise when we applied this model to OP-MEG data. SignificanceReal-time implementation of this method could reduce passive shielding requirements for OP-MEG recording and allow the measurement of low-frequency brain activity during natural participant movement.
- Citations
- 56
- FWCI
- 3.69
- Field percentile
- top 5%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Using OPMs to measure neural activity in standing, mobile participants
Robert A. Seymour, Nicholas Alexander, … Eleanor A. Maguire·NeuroImagePeer-reviewed·Sep 21, 2021
- Using OPM-MEG in contrasting magnetic environments
Ryan M. Hill, Jasen Devasagayam, … Matthew J. Brookes·NeuroImagePeer-reviewed·Mar 9, 2022
- A Novel, Robust, and Portable Platform for Magnetoencephalography using Optically Pumped Magnetometers
Holly Schofield, Ryan M. Hill, … Matthew J. Brookes·Imaging NeurosciencePeer-reviewed·Jan 1, 2024
- Noise Reduction and Localization Accuracy in a Mobile Magnetoencephalography System
T. Bardouille, V. Smith, … N. Holmes·bioRxiv·Mar 20, 2024
- On-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers
Joonas Iivanainen, Rasmus Zetter, … Lauri T. Parkkonen·NeuroImagePeer-reviewed·Mar 15, 2019
- Motion tolerance in wearable OPM-MEG using dynamic field nulling
Mainak Jas, Teppei Matsubara, … Seppo P. Ahlfors·bioRxiv·Aug 31, 2026