NeuroImageNeurosciencePeer-reviewed journal article
On-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers
Joonas IivanaineniD, Rasmus ZetteriD, Mikael GröniD, Karoliina Hakkarainen, Lauri T. ParkkoneniD
- Citations
- 269
- FWCI
- 11.45
- Field percentile
- top 1%
Abstract
The spatial resolution of magnetoencephalography (MEG) can be increased from that of conventional SQUID-based systems by employing on-scalp sensor arrays of e.g. optically-pumped magnetometers (OPMs). However, OPMs reach sufficient sensitivity for neuromagnetic measurements only when operated in a very low absolute magnetic field of few nanoteslas or less, usually not reached in a typical magnetically shielded room constructed for SQUID-based MEG. Moreover, field drifts affect the calibration of OPMs. Static and dynamic control of the ambient field is thus necessary for good-quality neuromagnetic measurements with OPMs. Here, we describe an on-scalp MEG system that utilizes OPMs and external compensation coils that provide static and dynamic shielding against ambient fields.\n\nIn a conventional two-layer magnetically shielded room, our coil system reduced the maximum remanent DC-field component within an 8-channel OPM array from 70 to less than 1 nT, enabling the sensors to operate in the sensitive spin exchange relaxation-free regime. When compensating field drifts below 4 Hz, a low-frequency shielding factor of 22 dB was achieved, which reduced the peak-to-peak drift from 1.3 to 0.4 nT and thereby the standard deviation of the sensor calibration from 1.6% to 0.4%. Without band-limiting the field that is compensated, a low-frequency shielding factor of 43 dB was achieved.\n\nWe validated the system by measuring brain responses to electric stimulation of the median nerve. With dynamic shielding and digital interference suppression methods, single-trial somatosensory evoked responses could be detected. Our results advance the deployment of OPM-based on-scalp MEG in lighter magnetic shields.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Measuring MEG closer to the brain: Performance of on-scalp sensor arrays
Joonas Iivanainen, Matti Stenroos, Lauri T. Parkkonen·NeuroImagePeer-reviewed·Dec 19, 2016
- Using OPM-MEG in contrasting magnetic environments
Ryan M. Hill, Jasen Devasagayam, … Matthew J. Brookes·NeuroImagePeer-reviewed·Mar 9, 2022
- A Novel, Robust, and Portable Platform for Magnetoencephalography using Optically Pumped Magnetometers
Holly Schofield, Ryan M. Hill, … Matthew J. Brookes·Imaging NeurosciencePeer-reviewed·Jan 1, 2024
- Detection of the 40-Hz Auditory Steady-state Response with Optically Pumped Magnetometers
Kyung‐min An, Jeong Hyun Shim, … Kiwoong Kim·Scientific ReportsPeer-reviewed·Oct 26, 2022
- Noise Reduction and Localization Accuracy in a Mobile Magnetoencephalography System
T. Bardouille, V. Smith, … N. Holmes·bioRxiv·Mar 20, 2024
- Magnetic Field Mapping and Correction for Moving OP-MEG
Stephanie Mellor, Tim M. Tierney, … Gareth Robert Barnes·IEEE Transactions on Biomedical EngineeringPeer-reviewed·Jul 29, 2021