Using OPM-MEG in contrasting magnetic environments
Ryan M. HilliD, Jasen DevasagayamiD, Niall HolmesiD, Elena BotoiD, Vishal ShahiD, James Osborne, Kristina SafariD, Frank WorcesteriD, Christopher Mariani, Eliot Dawson, David WoolgeriD, Richard W BowtelliD, Margot J. TayloriD, Matthew J. BrookesiD
Abstract
Magnetoencephalography (MEG) has been revolutionised in recent years by optically pumped magnetometers (OPMs). "OPM-MEG" offers higher sensitivity, better spatial resolution and lower cost than conventional instrumentation based on superconducting quantum interference devices (SQUIDS). Moreover, OPMs offer the possibility of motion robustness and lifespan compliance, dramatically expanding the range of MEG applications. However, OPM-MEG remains nascent technology; it places stringent requirements on magnetic shielding, and whilst a number of viable systems exist, most are custom made and there have been no cross-site investigations showing the reliability of data. In this paper, we undertake the first cross-site OPM-MEG comparison, using near identical commercial systems scanning the same participant. The two sites are deliberately contrasting, with different magnetic environments: a "green field" campus university site with an OPM-optimised shielded room (low interference) and a city centre hospital site with a "standard" (non-optimised) MSR (high interference). We show that despite a 25-fold difference in background field, and a 30-fold difference in low frequency interference, using dynamic field control and software-based suppression of interference we can generate comparable noise floors at both sites. In human data recorded during a visuo-motor task and a face processing paradigm, we were able to generate similar data, with source localisation showing that brain regions could be pinpointed with just ~10 mm spatial discrepancy and temporal correlations of > 80%. Overall, our study demonstrates that "plug- and-play" OPM-MEG systems exist and can be sited even in challenging magnetic environments.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 81
- FWCI
- 7.12
- Field percentile
- top 2%
- Organism
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- On-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers
Joonas Iivanainen, Rasmus Zetter, … Lauri T. Parkkonen·NeuroImagePeer-reviewed·Mar 15, 2019
- A Novel, Robust, and Portable Platform for Magnetoencephalography using Optically Pumped Magnetometers
Holly Schofield, Ryan M. Hill, … Matthew J. Brookes·Imaging NeurosciencePeer-reviewed·Jan 1, 2024
- Measuring MEG closer to the brain: Performance of on-scalp sensor arrays
Joonas Iivanainen, Matti Stenroos, Lauri T. Parkkonen·NeuroImagePeer-reviewed·Dec 19, 2016
- Magnetic Field Mapping and Correction for Moving OP-MEG
Stephanie Mellor, Tim M. Tierney, … Gareth Robert Barnes·IEEE Transactions on Biomedical EngineeringPeer-reviewed·Jul 29, 2021
- Multi-Channel Whole-Head OPM-MEG: Helmet Design and a Comparison with a Conventional System
Ryan M. Hill, Elena Boto, … Matthew J. Brookes·NeuroImagePeer-reviewed·May 29, 2020
- Noise Reduction and Localization Accuracy in a Mobile Magnetoencephalography System
Timothy Bardouille, Vanessa Smith, … Niall Holmes·SensorsPeer-reviewed·May 29, 2024