Noise-robust, physical microscopic deconvolution algorithm enabled by multi-resolution analysis regularization
Abstract
Despite the grand advances in fluorescence microscopy, the photon budget of fluorescent molecules remains the fundamental limiting factor for major imaging parameters, such as temporal resolution, duration, contrast, and even spatial resolution. Computational methods can strategically utilize the fluorescence photons against the imaging noise, to break the abovementioned limits. Here, we propose a multi-resolution analysis (MRA) approach to recharacterize and extract the two main characteristics of fluorescence images: (1) high contrast across the edge, and (2) high continuity along the edge. By regularizing the solution using framelet and curvelet domain sparsity, we develop MRA deconvolution algorithm for fluorescence image, which allows fine detail recovery even with negative signal-to-noise-ratio (SNR), and can provide more than 2-fold physical resolution enhancement with conspicuously fewer artifacts than maximum likelihood estimation (MLE) methods. Furthermore, we develop DeepMRA deconvolution algorithm that can provide computational background inhibition through a bias thresholding mechanism while deconvolving a fluorescence image. Compared with conventional background mitigation schemes, this novel deconvolution canonical form can deal with severer background and better preserve the high-frequency and low-intensity details, which are commonly disrupted by other algorithms. We demonstrate that the MRA and DeepMRA deconvolution algorithms can improve the SNR and resolution of biological images in various microscopies, such as wide-field, confocal, spinning-disk confocal (SD-confocal), light-sheet, structured illumination microscopy (SIM), and stimulated excitation depletion (STED) microscopy.
02 /Specification & Classification
Click any tag to browse matching papersReproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Resolution enhancement with deblurring by pixel reassignment (DPR)
B. Zhao, J. Mertz·Advanced PhotonicsPeer-reviewed·Oct 27, 2023
- Fourier ring correlation simplifies image restoration in fluorescence microscopy
Sami Koho, Giorgio Tortarolo, … Giuseppe Vicidomini·Nature CommunicationsPeer-reviewed·Jul 15, 2019
- Content-Aware Image Restoration: Pushing the Limits of Fluorescence Microscopy
MARTIN G. WEIGERT, Uwe Schmidt, … Eugene Wimberly Myers·Nature MethodsPeer-reviewed·Nov 19, 2018
- High-throughput 3D super-resolution imaging in deep tissue
Zhenhong Du, Jiajia Chen, … Ke Si·bioRxiv·Mar 7, 2025
- Independent noise realizations enable morphologically agnostic image reconstruction in single-photon-sensitive microscopy
Lisa Cuneo, Alessandro Zunino, … Giuseppe Vicidomini·bioRxiv·Sep 18, 2026
- Calibration-free single-frame super-resolution fluorescence microscopy
Anežka Dostálová, Dominik Vašinka, … Miroslav Ježek·Laser & Photonics ReviewPeer-reviewed·Aug 15, 2026