Abstract

The COVID-19 pandemic has resulted in increased need for diagnostic testing using reverse transcriptase real-time PCR (RT-PCR). An exponential increase in demand has resulted in a shortage of numerous reagents in particular those associated with the lysis buffer required to extract the viral RNA. Herein, we describe a rapid collective effort by hospital laboratory scientists, academic researchers and the biopharma industry to generate a validated lysis buffer. We have formulated a 4M Guanidinium thiocyanate (GITC)/ Triton X-100 Lysis buffer which provides comparable results with the recommended reagents. This buffer will ease the burden on hospital labs in their heroic efforts to diagnose a large population of patients.

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.