Scientific ReportsNeurosciencePeer-reviewed journal article
Improved spatio-temporal measurements of visually evoked fields using optically-pumped magnetometers
Aikaterini GialopsouiD, C. AbeliD, Tim M. James, Thomas CoussensiD, Mark G. BasoniD, Reuben K. Puddy, Francesco Di LorenzoiD, Katharina RolfsiD, Jens VoigtiD, Tilmann H. SanderiD, Mara CercignaniiD, P. KrügeriD
Abstract
Recent developments in performance and practicality of optically pumped magnetometers have enabled new capabilities in non-invasive brain function mapping through magnetoencephalography. In particular the lack of need of cryogenic operating conditions allows for more flexible placement of the sensor heads closer to the brain surface, leading to improved spatial measurement resolution and increased source localisation capabilities. Through the recording of visually evoked brain fields (VEF), we demonstrate that the closer sensor proximity can be further exploited to improve the temporal resolution. We use optically pumped magnetometers (OPMs), and for reference superconducting quantum interference devices (SQUIDs), to measure brain responses to standard flash and pattern reversal stimuli. We find highly reproducible signals with consistency across multiple healthy participants, stimulus paradigms and sensor modalities. The temporal resolution advantage of OPMs is manifest in a fourfold improvement of the ratio of magnetic signal peak height to temporal width, compared to SQUIDs. The resulting capability of improved spatio-temporal signal tracing is illustrated by simultaneous vector recordings of VEFs in the primary (V1) and associative (V2) visual cortex, where a time lag on the order of 10-20 ms is consistently found. This paves the way for further studies of spatio-temporal neurophysiological signal tracking in visual stimulus processing and other brain responses with potentially far-reaching consequences for time-critical mapping of functionality in the healthy and pathological brains.
- Citations
- 22
- FWCI
- 1.20
- Field percentile
- top 22%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Detection of the 40-Hz Auditory Steady-state Response with Optically Pumped Magnetometers
Kyung‐min An, Jeong Hyun Shim, … Kiwoong Kim·Scientific ReportsPeer-reviewed·Oct 26, 2022
- Decoding with multivariate pattern analysis is superior for optically pumped magnetometer-based magnetoencephalography compared to superconducting quantum interference device-based systems
Junlin Liang, Yulia Bezsudnova, … Ole B. Jensen·bioRxiv·Oct 14, 2025
- A Novel, Robust, and Portable Platform for Magnetoencephalography using Optically Pumped Magnetometers
Holly Schofield, Ryan M. Hill, … Matthew J. Brookes·Imaging NeurosciencePeer-reviewed·Jan 1, 2024
- Using OPM-MEG in contrasting magnetic environments
Ryan M. Hill, Jasen Devasagayam, … Matthew J. Brookes·NeuroImagePeer-reviewed·Mar 9, 2022
- Pushing the boundaries of MEG based on optically pumped magnetometers towards early human life
Pierre Corvilain, Vincent Wens, … Julie Bertels·Imaging NeurosciencePeer-reviewed·Jan 1, 2025
- Reliability and signal comparison of OPM-MEG, fMRI & iEEG in a repeated movie viewing paradigm
Olivia R. Christiano, Sebastian Michelmann·Imaging NeurosciencePeer-reviewed·Jan 1, 2026