Real-Time Selective Sequencing with RUBRIC: Read Until with Basecall and Reference-Informed Criteria
Harrison S. EdwardsiD, Raga KrishnakumariD, Anupama SinhaiD, Sara W. Bird, Kamlesh D. PateliD, Michael S. BartschiD
Abstract
The Oxford MinION, the first commercial nanopore sequencer, is also the first to implement molecule-by-molecule real-time selective sequencing or "Read Until". As DNA transits a MinION nanopore, real-time pore current data can be accessed and analyzed to provide active feedback to that pore. Fragments of interest are sequenced by default, while DNA deemed non-informative is rejected by reversing the pore bias to eject the strand, providing a novel means of background depletion and/or target enrichment. In contrast to the previously published pattern-matching Read Until approach, our RUBRIC method is the first example of real-time selective sequencing where on-line basecalling enables alignment against conventional nucleic acid references to provide the basis for sequence/reject decisions. We evaluate RUBRIC performance across a range of optimizable parameters, apply it to mixed human/bacteria and CRISPR/Cas9-cut samples, and present a generalized model for estimating real-time selection performance as a function of sample composition and computing configuration.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 67
- FWCI
- 2.38
- Field percentile
- top 12%
- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Real time selective sequencing using nanopore technology.
Matthew Loose, Sunir Malla, Michael Stout·Nature MethodsPeer-reviewed·Jul 25, 2016
- Dynamic, adaptive sampling during nanopore sequencing using Bayesian experimental design
Lukas Weilguny, Nicola De Maio, … Nick Goldman·Nature BiotechnologyPeer-reviewed·Jan 2, 2023
- ReadBouncer: Precise and Scalable Adaptive Sampling for Nanopore Sequencing
Jens-Uwe Ulrich, Ahmad Lutfi, … Bernhard Y. Renard·bioRxiv·Feb 1, 2022
- DeepNano-blitz: A Fast Base Caller for MinION Nanopore Sequencers
Vladimír Boža, Peter Perešíni, … Tomáš Vinař·BioinformaticsPeer-reviewed·Apr 28, 2020
- INC-Seq: Accurate single molecule reads using nanopore sequencing
Chenhao Li, Kern Rei Chng, … Niranjan Nagarajan·GigasciencePeer-reviewed·Aug 2, 2016
- Nanopore device-based fingerprinting of RNA oligos and microRNAs enhanced with an Osmium tag.
Madiha Sultan, Anastassia Kanavarioti·Scientific ReportsPeer-reviewed·Oct 2, 2019