A benchmark of muscle models to length changes great and small
Matthew MillardiD, Norman StutzigiD, Jörg FehriD, Tobias SiebertiD
Abstract
Digital human body models are used to simulate injuries that occur as a result of vehicle collisions, vibration, sports, and falls. Given enough time the bodys musculature can generate force, affect the bodys movements, and change the risk of some injuries. The finite-element code LS-DYNA is often used to simulate the movements and injuries sustained by the digital human body models as a result of an accident. In this work, we evaluate the accuracy of the three muscle models in LS-DYNA (MAT_156, EHTMM, and the VEXAT) when simulating a range of experiments performed on isolated muscle: force-length-velocity experiments on maximally and sub-maximally stimulated muscle, active-lengthening experiments, and vibration experiments. The force-length-velocity experiments are included because these conditions are typical of the muscle activity that precedes an accident, while the active-lengthening and vibration experiments mimic conditions that can cause injury. The three models perform similarly during the maximally and sub-maximally activated force-length-velocity experiments, but noticeably differ in response to the active-lengthening and vibration experiments. The VEXAT model is able to generate the enhanced forces of biological muscle during active lengthening, while both the MAT_156 and EHTMM produce too little force. In response to vibration, the stiffness and damping of the VEXAT model closely follows the experimental data while the MAT_156 and EHTMM models differ substantially. The accuracy of the VEXAT model comes from two additional mechanical structures that are missing in the MAT_156 and EHTMM models: viscoelastic cross-bridges, and an active titin filament. To help others build on our work we have made our benchmark simulations and model code publicly available.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 6
- FWCI
- 0.57
- Field percentile
- top 44%
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- A three filament mechanistic model of musculotendon force and impedance
M. Millard, D. W. Franklin, W. Herzog·eLifePeer-reviewed·Sep 10, 2024
- Using muscle-tendon load limits to assess unphysiological musculoskeletal model deformation and Hill-type muscle parameter choice
Lennart V. Nölle, Isabell Wochner, … Syn Schmitt·PLoS ONEPeer-reviewed·Nov 14, 2024
- Biophysical model for predicting muscle short-range stiffness during movement
Tim J. van der Zee, Surabhi N. Simha, … Friedl De Groote·bioRxiv·Oct 31, 2025
- Accuracy of experimentally estimated muscle properties: Evaluation and improvement using a newly developed toolbox
Edwin D. H. M. Reuvers, Dinant A. Kistemaker·bioRxiv·Sep 29, 2025
- Using physiologically-based models to predict in vivo skeletal muscle energetics
Ryan N. Konno, Glen A. Lichtwark, Taylor J. M. Dick·Journal of Experimental BiologyPeer-reviewed·Feb 17, 2025
- Summary of muscle parameters for Hill-based muscle modeling in the human lower limb
Ross H. Miller·bioRxiv·Dec 7, 2016