Optimized breath detection algorithm in Electrical Impedance Tomography
D. Khodadad, S. Nordebo, B. Muller, A. Waldman, R. Yerworth, T. Becher, I. Frerichs, L. Sophocleos, A. Van Kaam, M. Miedema, N. Seifnaraghi, R. Bayford
Abstract
ObjectiveThis paper define a method for optimizing the breath delineation algorithms used in Electrical Impedance Tomography (EIT). In lung EIT the identification of the breath phases is central for generating tidal impedance variation images, subsequent data analysis and clinical evaluation. The optimisation of these algorithms is particularly important in neonatal care since the existing breath detectors developed for adults may give insufficient reliability in neonates due to their very irregular breathing pattern.\n\nApproachOur approach is generic in the sense that it relies on the definition of a gold standard and the associated definition of detector sensitivity and specificity, an optimisation criterion and a set of detector parameters to be investigated. The gold standard has been defined by 11 clinicians with previous experience with EIT and the performance of our approach is described and validated using a neonatal EIT dataset acquired within the EU-funded CRADL project.\n\nMain resultsThree different algorithms are proposed that are improving the breath detector performance by adding conditions on 1) maximum tidal breath rate obtained from zero-crossings of the EIT breathing signal, 2) minimum tidal impedance amplitude and 3) minimum tidal breath rate obtained from Time-Frequency (TF) analysis.\n\nSignificanceBased on the gold standard, the most crucial parameters of the proposed algorithms are optimised by using a simple exhaustive search and a weighted metric defined in connection with the Receiver Operating Characterics (ROC). This provides a practical way to achieve any desirable trade-off between the sensitivity and the specificity of the detectors.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- A 3D Reconstruction Algorithm for Real-time Simultaneous Multi-Source EIT Imaging for Lung Function Monitoring
T.-J. Kao, B. Amm, … J. L. Mueller·bioRxiv·May 29, 2020
- Automated detection of artefacts in neonatal EEG with residual neural networks
Lachlan Webb, Minna Kauppila, … Nathan J. Stevenson·Computer Methods and Programs in BiomedicinePeer-reviewed·May 24, 2021
- Adjusting ADJUST: Optimizing the ADJUST Algorithm for Pediatric Data Using Geodesic Nets
Stephanie C. Leach, Santiago Morales, … Nathan A. Fox·PsychophysiologyPeer-reviewed·Mar 17, 2020
- A Reusable Non-Adhesive Chest-Wall Acoustic Wearable Estimates Respiratory Rate During Rest and Exercise
Lisa Haxel, Antonia Schroff, … John W. Dickinson·bioRxiv·Jun 19, 2026
- Multimodal electrical impedance tomography and electroencephalography imaging: Does higher skull conductivity resolution in EIT imaging improve accuracy of EEG source localization?
Ville Rimpiläinen, Alexandra Koulouri·bioRxiv·Aug 5, 2024
- Accuracy of a battery-powered portable capnometer in neonates
E. Hirakawa, S. Ibara·bioRxiv·Jun 5, 2020