A 3D Reconstruction Algorithm for Real-time Simultaneous Multi-Source EIT Imaging for Lung Function Monitoring
T.-J. Kao, B. Amm, D. Isaacson, J. Newell, G. Saulnier, J. L. Mueller
Abstract
Monitoring regional pulmonary ventilation and pulsatile perfusion changes in a 3D region of interest (ROI) of the lung is a promising application for electrical impedance tomography (EIT). This paper describes a 3D analytical reconstruction algorithm that was embedded in a prototype EIT system to enable a real-time image reconstruction at nearly 20 frames per second for monitoring impedance changes in the chest in real-time. The derivation and results of the 3D analytical forward solution and inverse solution and details of the real-time reconstruction algorithm are given. The algorithm and EIT system are validated with simulated data, in-vitro phantoms, and finally shown to be capable of imaging ventilation and pulsatile perfusion in human subjects. The human subject data was obtained using a high-precision, high-speed and simultaneous multiple current source (SMS-EIT) developed by GE Research. Data was collected using four rows of 8 electrodes for a healthy adult male subject and 2 rows of 16 electrodes for six healthy human female subjects, with one row placed above the breasts and a second row placed at the infra-mammary fold. Each of the female subjects performed a breathing maneuver with a volumetric incentive spirometer, and the volume of air inhaled was calculated from the EIT images. Pulsatile perfusion images were computed from this data, and regional lung filling was also analyzed.
02 /Specification & Classification
Click any tag to browse matching papers- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Optimized breath detection algorithm in Electrical Impedance Tomography
D. Khodadad, S. Nordebo, … R. Bayford·bioRxiv·Feb 23, 2018
- Multimodal electrical impedance tomography and electroencephalography imaging: Does higher skull conductivity resolution in EIT imaging improve accuracy of EEG source localization?
Ville Rimpiläinen, Alexandra Koulouri·bioRxiv·Aug 5, 2024
- Spherical Echo-Planar Time-resolved Imaging (sEPTI) for rapid 3D quantitative T2* and Susceptibility imaging
Nan Wang, Congyu Liao, … Kawin Setsompop·Magnetic Resonance in MedicinePeer-reviewed·Sep 9, 2024
- 3D Echo Planar Time-resolved Imaging (3D-EPTI) for ultrafast multi-parametric quantitative MRI
F. Wang, Z. Dong, … K. Setsompop·bioRxiv·May 6, 2021
- Toward Electrical Impedance Tomography of Functional Activity in the Retina
Enrico Ravagli, Alistair McEwan, … Kirill Y. Aristovich·bioRxiv·Oct 24, 2026
- High-Resolution EEG Source Reconstruction with Boundary Element Fast Multipole Method Using Reciprocity Principle and TES Forward Model Matrix
William A. Wartman, Tommi Raij, … Sergey N Makaroff·bioRxiv·Oct 30, 2022