Using the NoiSee workflow to measure signal-to-noise ratios of confocal microscopes
A. Ferrand, K. D. Schleicher, N. Ehrenfeuchter, W. Heusermann, O. Biehlmaier
Abstract
Confocal microscopy is used today on a daily basis in life science labs. This \"routine\" technique contributes to the progress of scientific projects across many fields by revealing structural details and molecular localization, but researchers need to be aware that detection efficiency and emission light path performance is of major influence in the confocal image quality. By design, a large portion of the signal is discarded in confocal imaging, leading to a decreased signal-to-noise ratio (SNR) which in turn limits resolution. A well-aligned system and high performance detectors are needed in order to generate an image of best quality. However, a convenient method to address system status and performance on the emission side is still lacking. Here, we present a complete method to assess microscope and emission light path performance in terms of SNR, with a comprehensive protocol alongside NoiSee, an easy-to-use macro for Fiji (available via the corresponding update site). We used this method to compare several confocal systems in our facility on biological samples under typical imaging conditions. Our method reveals differences in microscope performance and highlights the various detector types used (multialkali photomultiplier tube (PMT), gallium arsenide phosphide (GaAsP) PMT, and Hybrid detector). Altogether, our method will provide useful information to research groups and facilities to diagnose their confocal microscopes.
02 /Specification & Classification
Click any tag to browse matching papersReproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Signal to Noise Ratio as a Cross-Platform Metric for Intraoperative Fluorescence Imaging
A. Gharia, E. P. Philip Papageorgiou, … M. Anwar·bioRxiv·Nov 20, 2019
- Variance lower bound on fluorescence microscopy image denoising
- Long-term quality assessment and monitoring of light microscope performance through accessible and reliable protocols, tools and metrics
O. Faklaris, L. Bancel-Vallee, … T. Guilbert·bioRxiv·Jun 16, 2021
- Confocal imaging capacity on a widefield microscope using a spatial light modulator
Y. L. Wang, N. W. F. Grooms, … S. H. Chung·bioRxiv·Dec 3, 2020
- Monitoring microscope performance in an imaging facility using OMERO-metrics.
Sophia Sommer, Oumou Dhmine, … Ian M. Dobbie·bioRxiv·Jul 1, 2026
- Real-time Image Denoising of Mixed Poisson-Gaussian Noise in Fluorescence Microscopy Images using ImageJ
Varun Mannam, Yide Zhang, … Scott S. Howard·OpticaPeer-reviewed·Feb 8, 2022