bioRxivBiophysicsPreprint
The impact of uncertainty in hERG binding mechanism on in silico predictions of drug-induced proarrhythmic risk
Abstract
Background and PurposeDrug-induced reduction of the rapid delayed rectifier potassium current carried by the human Ether-a-go-go-Related Gene (hERG) channel is associated with increased risk of arrhythmias. Recent updates to drug safety regulatory guidelines attempt to capture each drugs hERG binding mechanism by combining in vitro assays with in silico simulations. In this study, we investigate the impact on in silico proarrhythmic risk predictions due to uncertainty in the hERG binding mechanism and physiological hERG current model. Experimental ApproachPossible pharmacological binding models were designed for the hERG channel to account for known and postulated small molecule binding mechanisms. After selecting a subset of plausible binding models for each compound through calibration to available voltage-clamp electrophysiology data, we assessed their effects, and the effects of different physiological models, on proarrhythmic risk predictions. Key ResultsFor some compounds, multiple binding mechanisms can explain the same data produced under the safety testing guidelines, which results in different inferred binding rates. This can result in substantial uncertainty in the predicted torsade risk, which often spans more than one risk category. By comparison, we found that the effect of a different hERG physiological current model on risk classification was subtle. Conclusion and ImplicationsThe approach developed in this study assesses the impact of uncertainty in hERG binding mechanisms on predictions of drug-induced proarrhythmic risk. For some compounds, these results imply the need for additional binding data to decrease uncertainty in safety-critical applications.
- organism: human
- assay: electrophysiology
- research focus: drug response / drug discovery
- approach: statistical model
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Prediction of TdP Arrhythmia Risk Through Molecular Simulations of Conformation-specific Drug Interactions with the hERG K+, NaV1.5, and CaV1.2 Channels
Kyle C. Rouen, Kush Narang, … Igor V. Vorobyov·bioRxiv·Sep 25, 2025
- Optimising experimental designs for model selection of ion channel drug binding mechanisms
Frankie Patten-Elliott, Chon Lok Lei, … Gary R. Mirams·Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering SciencesPeer-reviewed·Mar 13, 2025
- Toward in vivo-relevant hERG safety assessment and mitigation strategies based on relationships between non-equilibrium blocker binding, three-dimensional channel-blocker interactions, dynamic occupancy, dynamic exposure, and cellular arrhythmia
H. Wan, G. Selvaggio, R. A. Pearlstein·bioRxiv·Jun 8, 2020
- Atomistic modeling towards predictive cardiotoxicity
K. R. DeMarco, J. R. D. Dawson, … I. Vorobyov·bioRxiv·May 11, 2019
- hERG-LTN: A New Paradigm in hERG Cardiotoxicity Assessment Using Neuro-Symbolic and Generative AI Embedding (MegaMolBART, Llama3.2, Gemini, DeepSeek) Approach
Delower Hossain, Fuad Al Abir, Jake Y. Chen·bioRxiv·Feb 17, 2025
- Transmural and rate-dependent profiling of drug-induced arrhythmogenic risks through in silico simulations of multichannel pharmacology