In Vivo Measurements of the Frequency-Dependent Impedance of the Spinal Cord
Marcel UtziD, John W. Miller, Chandan G. Reddy, Saul Wilson, Kingsley O. Abode-Iyamah, Douglas C. Fredericks, George T. Gillies, Matthew A. Howard
Abstract
Improved knowledge of the electrode-tissue impedance will be useful in optimizing the clinical protocols and resulting efficacy of the existing and emerging approaches to spinal cord stimulation. Toward that end, the complex impedance (amplitude and phase) of in vivo ovine spinal cord tissue was measured at the electrode-pial subdural surface interface from 5 Hz to 1 MHz, and with the bi-polar electrodes oriented both parallel and perpendicular to the rostral-caudal axis of the spinal cord. At stimulation frequencies above 10 kHz, most of the impedance then becomes resistive in nature and the phase diference between the stimulation signal and the resulting current drops to {approx} 10{ring}, thus maximizing power transfer to the tissues. Also, at these higher frequencies, the current pulse maintains significantly greater fidelity to the shape of the stimulation signal applied across the electrodes. Lastly, there were lower impedances associated with parallel as opposed to perpendicular orientation of the electrodes, thus reflecting the effects of fiber orientation within the spinal cord. Impedance differences of this kind have not been reported with epidural stimulation because of the electrical shunting effects of the intervening layer of relatively high conductivity cerebrospinal fluid. These observations provide a quantitative basis for improved models of spinal cord stimulation and suggest certain advantages for direct intradural stimulation relative to the standard epidural approaches. (Some figures in this article are in colour only in the electronic version)
02 /Specification & Classification
Click any tag to browse matching papersReproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Frequency-dependent and capacitive tissue electrical properties in spinal cord stimulation models
Niranjan Khadka, Boshuo Wang, Marom Bikson·Journal of Neural EngineeringPeer-reviewed·May 12, 2025
- Changes in spinal cord hemodynamic reflect modulation of spinal network with different parameters of epidural stimulation
Shanshan Tang, Carlos A. Cuellar, … Igor Aleksandrovich Lavrov·NeuroImagePeer-reviewed·Jul 20, 2020
- Electrode position, distance, size, and orientation determine efficacy of cervical epidural stimulation to recruit forelimb muscles in rats
Andrés Pascual-Leone, Vishweshwar Tyagi, … Jason B. Carmel·bioRxiv·Sep 5, 2025
- Intraoperative electrical stimulation of the human dorsal spinal cord reveals a map of arm and hand muscle responses
James R. McIntosh, Evan F. Joiner, … Jason B. Carmel·Journal of NeurophysiologyPeer-reviewed·Nov 23, 2022
- High-Frequency Stimulation Does Not Improve Comfort of Transcutaneous Spinal Cord Stimulation
Ashley N Dalrymple, Charli Ann Hooper, … Douglas J. Weber·bioRxiv·Sep 6, 2022
- Spinal facilitation of descending motor input
Giuliano Taccola, Roger W. P. Kissane, … Victor Reggie Edgerton·bioRxiv·Jun 30, 2023