"Select and retrieve via direct upsampling" network (SARDU-Net): a data-driven, model-free, deep learning approach for quantitative MRI protocol design

F. Grussu, S. B. Blumberg, M. Battiston, L. S. Kakkar, H. Lin, A. Ianus, T. Schneider, S. Singh, R. Bourne, S. Punwani, D. Atkinson, C. A. M. Gandini Wheeler-kingshott, E. Panagiotaki, T. Mertzanidou, D. C. Alexander

PDFDOI

Abstract

PurposeWe introduce "Select and retrieve via direct upsampling" network (SARDU-Net), a data-driven framework for model-free quantitative MRI (qMRI) protocol design, and demonstrate it on in vivo brain and prostate diffusion-relaxation imaging (DRI). MethodsSARDU-Net selects subsets of informative measurements within lengthy pilot scans, without the requirement to identify tissue parameters for which to optimise for. The algorithm consists of a selector, identifying measurement subsets, and a predictor, estimating fully-sampled signals from the subsets. We implement both using deep neural networks, which are trained jointly end-to-end. We demonstrate the algorithm on brain (32 diffusion-/T1-weightings) and prostate (16 diffusion-/T2-weightings) DRI scans acquired on 3 healthy volunteers on two separate 3T Philips systems each. We used SARDU-Net to identify sub-protocols of fixed size, assessing the reproducibility of the procedure and testing sub-protocols for their potential to inform multi-contrast analyses via T1-weighted spherical mean diffusion tensor (T1-SMDT, brain) and hybrid multi-dimensional MRI (HM-MRI, prostate) modelling. ResultsIn both brain and prostate, SARDU-Net identifies sub-protocols that maximise information content in a reproducible manner across training instantiations. The sub-protocols enable multi-contrast modelling for which they were not optimised explicitly, providing robust T1-SMDT and HM-MRI maps and goodness-of-fit in the top 5% against extensive sub-protocol comparisons. ConclusionsSARDU-Net gives new opportunities to identify economical but informative qMRI protocols from a subset of the pilot scans that can be used for acquisition-time-sensitive applications. The simple architecture makes the algorithm easy to train when exhaustive searches are intractable, and applicable to a variety of anatomical contexts.

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.

Similarity Map
SelectedSame fieldCross-field
THISBollmann '19Grussu '21Eggl '24Cieslak '20Martins '21Khajehim '21
65% semantic matchNeuroscience
Steffen Bollmann, Matilde Holm Kristensen, Morten Skaarup Larsen+7 more·Zeitschrift für Medizinische Physik·Feb 14, 2019· 31 citations