Eye tracking-based estimation and compensation of chromatic offsets for multi-wavelength retinal microstimulation with foveal cone precision
N. Domdei, M. Linden, J. L. Reiniger, F. G. Holz, W. M. Harmening
Abstract
Multi-wavelength ophthalmic imaging and stimulation of photoreceptor cells requires consideration of chromatic dispersion of the eye, manifesting in longitudinal and transverse chromatic aberrations. Current image-based techniques to measure and correct transverse chromatic aberration (TCA) and the resulting transverse chromatic offset (TCO) in an adaptive optics retinal imaging system are precise, but lack compensation of small but significant shifts in eye position occurring during in vivo testing. Here we present a method that requires only a single measurement of TCO during controlled movements of the eye to map retinal chromatic image shifts to the image space of a pupil camera. After such calibration, TCO can be compensated by continuously monitoring eye position during experimentation and by interpolating correction vectors from a linear fit to the calibration data. The average change rate of TCO per head shift and the correlation between Kappa and the individual foveal TCA are close to the expectations based on a chromatic eye model. Our solution enables continuous correction of TCO with high spatial precision and avoids high light intensities required for re-measuring TCO after eye position changes, which is necessary for foveal cone-targeted psychophysical experimentation.
02 /Specification & Classification
Click any tag to browse matching papers- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Transverse chromatic offsets with pupil displacements in the human eye: Sources of variability and methods for real-time correction
Alexandra E. Boehm, Claudio Michele Privitera, … Austin Roorda·Biomedical Optics ExpressPeer-reviewed·Mar 6, 2019
- Determination and correction of aberrations in full field OCT using phase gradient autofocus by maximizing the likelihood function
V. Matkivsky, A. Moiseev, … G. Gelikonov·bioRxiv·May 12, 2020
- Volumetric montaging of optical coherence tomography in human retinas
Raymond S. Fang, Fengyuanshan Xu, … Hao F. Zhang·bioRxiv·Feb 23, 2026
- Coarse-scale Optoretinography(CoORG) with extended field-of-view for normative characterization.
X. Jiang, T. Liu, … R. Sabesan·bioRxiv·Sep 8, 2022
- Closed-loop optical optimization enables patterned retinal stimulation in vivo at cellular scales
Justin Chen, Fengyuanshan Xu, … Hao F. Zhang·bioRxiv·Aug 10, 2026
- Functional retinal imaging using adaptive optics swept-source OCT at 1.6MHz
M. Azimipour, J. V. Migacz, … R. S. Jonnal·bioRxiv·Sep 18, 2018