Volumetric montaging of optical coherence tomography in human retinas
Raymond S. FangiD, Fengyuanshan Xu, Daniel Kim, Ronald ZambranoiD, Alexander K. N. LamiD, Raphael Tinio, Cheng SuniD, Christopher Kai-Shun LeungiD, Joel S. SchumaniD, Rukhsana G. MirzaiD, Hao F. ZhangiD
Abstract
Optical coherence tomography (OCT) has transformed clinical eye care by providing high-resolution volumetric imaging of the retina. Recently, ultrawide-field-of-view (FOV) OCT played an increasingly significant clinical role; however, most clinical OCT systems offer only a rather limited FOV. We increased the FOV of clinical OCT by volumetrically montaging multiple OCT datasets in three dimensions (3D). We performed volumetric montaging by representing the internal limiting membrane (ILM) and retinal pigment epithelium (RPE) in each volume as point clouds and using these point clouds to compute transformations that map each volume to a common reference frame. We validated our methodology using datasets from three institutions with different OCT hardware and data-acquisition procedures. Using the mean surface distance between point clouds, we found the error in montaging was less than the lateral pixel size. Our method enabled existing clinical OCT to achieve ultrawide FOV imaging without any hardware modification.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- Organism
- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Large field-of-view incoherent volumetric imaging in living human retina by confocal oblique scanning laser ophthalmoscopy
- Freeform robotic optical coherence tomography beyond the optical field-of-view limit
Raymond S. Fang, Pengpeng Zhang, … Hao F. Zhang·IEEE Transactions on Medical ImagingPeer-reviewed·Jun 17, 2025
- Volumetric fluorescence imaging in a human eye model by oblique scanning laser ophthalmoscope (oSLO): a feasibility study
- Kilohertz retinal FF-SS-OCT and flood imaging with hardware-based adaptive optics
D. Valente, K. V. Vienola, … R. S. Jonnal·bioRxiv·Jul 23, 2020
- Second-generation dual-channel visible light optical coherence tomography enables wide-field, full-range, and shot-noise limited retinal imaging
- Vis-OCT Explorer: an open-source software for visible-light optical coherence tomography data processing
Weijia Fan, Fengyuanshan Xu, … Hao Zhang·Biomedical Optics ExpressPeer-reviewed·Mar 2, 2026