bioRxivNeurosciencePreprint
Diffusion-weighted steady-state free precession imaging in the ex vivo macaque brain on a 10.5T human MRI scanner
Benjamin C. TendleriD, Shaun WarringtoniD, Mohamed Kotb SelimiD, Wenchuan WuiD, Gregor AdrianyiD, Edward J. AuerbachiD, Alexander Bratch, H. FarooqiD, Noam HareliD, Sarah R. HeilbronneriD, Saâd JbabdiiD, Steve JungstiD, Christophe LengletiD, Ana M.G. ManeaiD, Steen MoelleriD, Franco PestilliiD, Pramod Kumar PisharadyiD, Kǎmil UǧurbiliD, Matt WaksiD, Essa S. YacoubiD, Stamatios N. SotiropoulosiD, Karla L. MilleriD, Jan ZimmermanniD
Abstract
Diffusion MRI provides a non-invasive probe of local fibre bundles and long-range anatomical connections to characterise the structural connectome. One way to achieve very high spatial resolution diffusion MRI data for connectivity investigations is to scan ex-vivo brains over many hours or days, ideally at ultra-high field strength to boost signal levels. However, conventional diffusion MRI acquisition techniques do not generally deliver good data quality for the challenging conditions of ex-vivo tissue, characterised by reduced diffusivities and relaxation times when compared to in vivo. In this work, we investigate the potential of the diffusion-weighted steady-state free precession (DW-SSFP) sequence for ex vivo diffusion imaging of the macaque brain using a 10.5 T human MRI scanner with a conventional (Gmax = 70 mT/m) gradient set. SNR-efficiency optimisations incorporating experimental relaxation times demonstrate that the DW-SSFP sequence is predicted to achieve improved or similar SNR efficiency compared to a diffusion-weighted spin- and stimulated-echo sequence. Importantly, DW-SSFP can achieve this with the additional benefit of negligible geometric distortions, unlike conventional diffusion MRI using an echo-planar imaging readout. Using optimised DW-SSFP sequence parameters, we propose a protocol at 0.4 mm isotropic resolution using a two-shell multi-orientation protocol (effective b-values of 3200 s/mm2 and 5600 s/mm2). We fit the data using Tensor, Ball and 3-Sticks and Constrained Spherical Deconvolution signal representations. The results demonstrate high-quality diffusivity estimates across the entire brain with the ability to resolve multiple fibre populations in challenging crossing-fibre regions. The data will be made fully open source and multimodal as part of the Center for Mesoscale Connectomics, providing a resource for future connectivity investigations.
- Citations
- 1
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- 10.5 Tesla High-Resolution Macaque Brain MRI for In vivo and Ex vivo Connectivity Studies
Shaun Warrington, Mohamed Kotb Selim, … Stamatios N. Sotiropoulos·bioRxiv·Aug 26, 2026
- A 48-Channel Receive Array Coil for Mesoscopic Diffusion-Weighted MRI of Human ex vivo Brain Imaging on the 3T Connectome Scanner
- Tissue Optimisation Strategies for High Quality Ex Vivo Diffusion Imaging
Rachel L. C. Barrett, Diana Cash, … Flavio Dell’Acqua·NMR in BiomedicinePeer-reviewed·Nov 2, 2022
- High-fidelity, high-spatial-resolution diffusion MRI of the ex-vivo whole human brain on the 3T Connectom scanner using structured low-rank EPI ghost correction
Gabriel Ramos‐Llordén, Rodrigo A. Lobos, … Susie Y. Huang·bioRxiv·Aug 1, 2021
- In vivo human whole-brain Connectom diffusion MRI dataset at 760 μm isotropic resolution
Fuyixue Wang, Zijing Dong, … Kawin Setsompop·Scientific DataPeer-reviewed·Apr 29, 2021
- Resolution and b value dependent Structural Connectome in ex vivo Mouse Brain
Stephanie Crater, Surendra Maharjan, … Nian Wang·NeuroImagePeer-reviewed·Apr 10, 2022