bioRxivBioengineering
A 48-Channel Receive Array Coil for Mesoscopic Diffusion-Weighted MRI of Human ex vivo Brain Imaging on the 3T Connectome Scanner
A. Scholz, R. Etzel, M. W. May, M. Mahmutovic, Q. Tian, G. Ramos-Llorden, B. Bilgic, T. Witzel, J. P. Stockmann, C. Mekkaoui, L. L. Wald, S. Y. Huang, A. Yendiki, B. Keil
Abstract
In vivo diffusion-weighted magnetic resonance imaging is limited in signal-to-noise-ratio (SNR) and acquisition time, which constrains spatial resolution to the macroscale regime. Ex vivo imaging, which allows for arbitrarily long scan times, is critical for exploring human brain structure in the mesoscale regime without loss of SNR. Standard head array coils designed for patients are sub-optimal for imaging ex vivo whole brain specimens. The goal of this work was to design and construct a 48-channel ex vivo whole brain array coil for high-resolution and high b-value diffusion-weighted imaging on a 3T Connectome scanner. The coil was validated with bench measurements and characterized by imaging metrics on an agar brain phantom and an ex vivo human brain sample. The two-segment coil former was constructed for a close fit to a whole human brain, with small receive elements distributed over the entire brain. Imaging tests including SNR and G-factor maps were compared to a 64-channel head coil designed for in vivo use. There was a 2.9-fold increase in SNR in the peripheral cortex and a 1.3-fold gain in the center when compared to the 64-ch head coil. The 48-channel ex vivo whole brain coil also decreases noise amplification in highly parallel imaging, allowing acceleration factors of approximately one unit higher for a given noise amplification level. The acquired diffusion-weighted images in a whole ex vivo brain specimen demonstrate the applicability of the developed coil for high-resolution and high b-value diffusion-weighted ex vivo brain MRI studies.
- organism: human
- assay: multiome
- research focus: imputation
- research focus: benchmarking
- approach: experimental assay
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- A 128-channel receive array with enhanced SNR performance for 10.5 tesla brain imaging
Russell Lagore, Alireza Sadeghi‐Tarakameh, … Kǎmil Uǧurbil·bioRxiv·Oct 20, 2024
- Diffusion-weighted steady-state free precession imaging in the ex vivo macaque brain on a 10.5T human MRI scanner
Benjamin C. Tendler, Shaun Warrington, … Jan Zimmermann·bioRxiv·Dec 16, 2025
- An RF coil array system for in vivo & ex vivo non-human primate brain studies at 10.5 Tesla
Matt Waks, Alexander Bratch, … Gregor Adriany·bioRxiv·Jun 3, 2026
- In vivo human whole-brain Connectom diffusion MRI dataset at 760 μm isotropic resolution
Fuyixue Wang, Zijing Dong, … Kawin Setsompop·Scientific DataPeer-reviewed·Apr 29, 2021
- Single Channel Strongly-Coupled Geometry Surface Coil for Small Mammal Whole Brain fMRI
Kyle Johnson, Hanbing Lu, Jason W. Sidabras·bioRxiv·Aug 7, 2026
- An 8 Dipole Transceive and 24 Loop Receive Array for Non-Human Primate Head Imaging at 10.5T
R. L. Lagore, S. Moeller, … G. Adriany·bioRxiv·Aug 27, 2020