Magnetic Resonance ImagingNeurosciencePeer-reviewed journal article
Empirical field mapping for gradient nonlinearity correction of multi-site diffusion weighted MRI
Colin B. HanseniD, Baxter P. RogersiD, Kurt G. SchillingiD, Vishwesh NathiD, Justin A. Blaber, Okan Irfanoglu, Alan Seth BarnettiD, Carlo M. PierpaoliiD, Adam W. AndersoniD, Bennett A. LandmaniD
Abstract
BackgroundAchieving inter-site / inter-scanner reproducibility of diffusion weighted magnetic resonance imaging (DW-MRI) metrics has been challenging given differences in acquisition protocols, analysis models, and hardware factors. PurposeMagnetic field gradients impart scanner-dependent spatial variations in the applied diffusion weighting that can be corrected if the gradient nonlinearities are known. However, retrieving manufacturer nonlinearity specifications is not well supported and may introduce errors in interpretation of units or coordinate systems. We propose an empirical approach to mapping the gradient nonlinearities with sequences that are supported across the major scanner vendors. Study TypeProspective observational study SubjectsA spherical isotropic diffusion phantom, and a single human control volunteer Field Strength/Sequence3T (two scanners). Stejskal-Tanner spin echo sequence with b-values of 1000, 2000 s/mm2 with 12, 32, and 384 diffusion gradient directions per shell. AssessmentWe compare the proposed correction with the prior approach using manufacturer specifications against typical diffusion pre-processing pipelines (i.e., ignoring spatial gradient nonlinearities). In phantom data, we evaluate metrics against the ground truth. In human and phantom data, we evaluate reproducibility across scans, sessions, and hardware. Statistical TestsWilcoxon rank-sum test between uncorrected and corrected data. ResultsIn phantom data, our correction method reduces variation in mean diffusivity across sessions over uncorrected data (p<0.05). In human data, we show that this method can also reduce variation in mean diffusivity across scanners (p<0.05). ConclusionOur method is relatively simple, fast, and can be applied retroactively. We advocate incorporating voxel-specific b-value and b-vector maps should be incorporated in DW-MRI harmonization preprocessing pipelines to improve quantitative accuracy of measured diffusion parameters.
- Citations
- 26
- FWCI
- 1.22
- Field percentile
- top 20%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Eddy current-induced artifacts correction in high gradient strength diffusion MRI with dynamic field monitoring: demonstration in ex vivo human brain imaging
G. Ramos Llorden, D. Park, … S. Y. Huang·bioRxiv·Feb 15, 2023
- Retrospective harmonization of multi-site diffusion MRI data acquired with different acquisition parameters
Suheyla Cetin Karayumak, Sylvain Bouix A, … Yogesh Rathi A·NeuroImagePeer-reviewed·Sep 8, 2018
- Distortion correction of diffusion weighted MRI without reverse phase-encoding scans or field-maps
K. G. Schilling, J. Blaber, … B. A. Landman·bioRxiv·Jan 19, 2020
- Computing the Orientational-Average of Diffusion-Weighted MRI Signals: A Comparison of Different Techniques
Maryam Afzali, Hans E. Knutsson, … Derek Kenton Jones·Scientific ReportsPeer-reviewed·Jul 12, 2021
- Spatial Image Gradient Estimation from the Diffusion MRI Profile
Iman Aganj, Thorsten Feiweier, … Andre J. W. van der Kouwe·Magnetic Resonance in MedicinePeer-reviewed·Jan 23, 2026
- Diffusion MRI Head Motion Correction Methods are Highly Accurate but Impacted by Denoising and Sampling Scheme
Matthew Cieslak, Philip A. Cook, … Theodore Daniel Satterthwaite·Human Brain MappingPeer-reviewed·Jan 30, 2024