Eliminating steam pops and improving lesion safety in atrial ablation with conductive hydrogels
A. D. Post, L. Jaworski, D. Bernard, D. Bashe, S. Goal, H. D. Zhang, A. Nkansah, E. Cosgriff-Hernandez, M. Razavi
Abstract
BackgroundAtrial fibrillation (AF) is a significant burden worldwide, and the existing treatments leave much to be desired. There are, however, opportunities to improve the safety and efficacy of the most popular treatment, radiofrequency (RF) cardiac ablation, using conductive hydrogels as an ablation mediator. MethodsLesions were created in ex vivo ventricular tissues using bare metal traditional RF catheters and three different hydrogels with varying conductivities to assess the effect of conductivity on lesion formation. Similar procedures were performed in atrial/esophageal tissue stacks to mimic physiological AF ablation and demonstrate the initial safety profile of conductive hydrogel-mediated ablation. ResultsThe hydrogel mediated lesions were overall shallower and narrower than bare metal, and also exhibited less char and improved lesion homogeneity. The hydrogel also eliminated steam pops. Finally, the hydrogel appeared to be more thermally protective of the esophagus in the atrial/esophageal tissue stack, greatly reducing the lesion formation on the esophagus while still achieving transmural lesions in the atrial tissue. ConclusionsHydrogel-mediated RF ablation holds promise as a novel method to improve ablation outcomes for AF patients. Future work will confirm this in vivo and establish the chemistry required to create a conductive hydrogel coating for RF ablation catheters.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Design of a Conductive Hydrogel Coating to Improve Catheter-Tissue Coupling in Radiofrequency Ablation
Derek Bashe, Octavio Jalife, … Elizabeth Cosgriff‐Hernandez·bioRxiv·May 7, 2026
- Dual cryo-radiofrequency ablation enhances lesion depth in beating human left ventricular preparations
M. Sulkin, J. Laughner, … I. R. Efimov·bioRxiv·Nov 14, 2018
- Successful stimulation of myocardial ganglionic plexuses by TAU 20 in the absence of cardiac damage
Shengzhe Li, Jamie Kay, … Rasheda A. Chowdhury·Frontiers in PhysiologyPeer-reviewed·Mar 28, 2025
- Computer Modeling of Radiofrequency Cardiac Ablation including Heartbeat-Induced Electrode Displacement
J. J. Perez, A. Gonzalez-Suarez, … E. Berjano·bioRxiv·Dec 11, 2021
- Quantification of thermal side effects during pulsed field ablation
Marcela Mercado‐Montoya, Tatiana Gomez Bustamante, … Lawrence Overzet·bioRxiv·Nov 2, 2024
- Comparison of therapeutic effects between pulsed field ablation and cryoballoon ablation in the treatment of atrial fibrillation: a systematic review and me-ta-analysis
Yun Wan, Shuting Zeng, … Jun Luo·Cardiology in ReviewPeer-reviewed·Nov 14, 2024