bioRxivPhysiology
Magnetic Resonance Spectroscopy as a Non-invasive Method to Quantify Muscle Carnosine in Humans: a Comprehensive Validity Assessment
V. d. E. Silva, V. d. S. Painelli, S. K. Shinjo, W. Ribeiro Pereira, E. M. Cilli, C. Sale, B. Gualano, M. C. Otaduy, G. G. Artioli
Abstract
Carnosine is a dipeptide abundantly found in human skeletal muscle, cardiac muscle and neuronal cells having numerous properties that confers performance enhancing effects, as well as a wide-range of potential therapeutic applications. A reliable and valid method for tissue carnosine quantification is crucial for advancing the knowledge on biological processes involved with carnosine metabolism. In this regard, proton magnetic resonance spectroscopy (1H-MRS) has been used as a non-invasive alternative to quantify carnosine in human skeletal muscle. However, carnosine quantification by 1H-MRS has some potential limitations that warrant a thorough experimental examination of its validity. The present investigation examined the reliability, accuracy and sensitivity for the determination of muscle carnosine in humans using in vitro and in vivo experiments and comparing it to reference method for carnosine quantification (high-performance liquid chromatography - HPLC). We used in vitro 1H-MRS to verify signal linearity and possible noise sources. Carnosine was determined in the m. gastrocnemius by 1H-MRS and HPLC to compare signal quality and convergent validity. 1H-MRS showed adequate discriminant validity, but limited reliability and poor agreement with a reference method. Low signal amplitude, low signal-to-noise ratio, and voxel repositioning are major sources of error.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Extensive profiling of histidine-containing dipeptides reveals species- and tissue-specific distribution and metabolism in mice, rats and humans
T. Van der Stede, J. Spaas, … W. Derave·bioRxiv·Feb 16, 2023
- Fast in vivo 23Na imaging and T2* mapping using accelerated 2D-FID magnetic resonance spectroscopic imaging at 3 T: Proof of concept and reliability study
A. A. Alhulail, P. Xia, … U. E. Emir·bioRxiv·May 25, 2020
- The intra-individual reliability of 1H-MRS measurement in the anterior cingulate cortex across one year
Mengyun Wang, Max Korbmacher, … Karsten Specht·Human Brain MappingPeer-reviewed·Nov 20, 2023
- Development and Validation of an LC-MS Method for Quantification of Sex Steroid Hormones in Skeletal Muscle
Viktor Engman, Séverine Lamon, Shaun A. Mason·SteroidsPeer-reviewed·Jun 24, 2026
- Musculoskeletal fat imaging and quantification by high-resolution metabolite cycling magnetic resonance spectroscopic imaging at 3 T: A fast method to generate separate distribution maps of lipid components
A. A. Alhulail, D. A. Patterson, … U. E. Emir·bioRxiv·Aug 12, 2019
- Human Skeletal Muscle has Large Capacity to Increase Carnosine Content in Response to Beta-Alanine Supplementation. A Systematic Review with Bayesian Individual and Aggregate Data E-Max Model and Meta-Analysis
N. S. Rezende, P. A. Swinton, … E. Dolan·bioRxiv·Dec 10, 2019