Science RoboticsNeurosciencePeer-reviewed journal article
A closed-loop hand prosthesis with simultaneous intraneural tactile and position feedback
Edoardo D’AnnaiD, Giacomo ValleiD, Alberto MazzoniiD, Ivo StraussiD, Francesco IberiteiD, Jérémy PattoniD, Francesco Maria PetriniiD, Staniša RaspopovićiD, Giuseppe GranataiD, Riccardo Di IorioiD, Marco ControzziiD, Christian CiprianiiD, Thomas StieglitziD, Paolo Maria RossiniiD, Silvestro MiceraiD
Abstract
Current myoelectric prostheses allow upper-limb amputees to regain voluntary motor control of their artificial limb by exploiting residual muscle function in the forearm1. However, the over-reliance on visual cues resulting from a lack of sensory feedback is a common complaint2,3. Recently, several groups have provided tactile feedback in upper-limb amputees by using implanted electrodes4,5,6,7,8, surface nerve stimulation9,10 or sensory substitution11,12. These approaches have led to improved function and prosthesis embodiment4,5,6,7,13,14. Nevertheless, the provided information remains limited to a subset of the rich sensory cues available to healthy individuals. More specifically, proprioception, the sense of limb position and movement, is predominantly absent from current systems. Here we show that sensory substitution based on intraneural stimulation can deliver position feedback in real-time and in conjunction with somatotopic tactile feedback. This approach allowed two trans-radial amputees to regain high and close-to-natural remapped proprioceptive acuity, with a median joint angle reproduction accuracy of 9.1{degrees} and a median threshold to detection of passive movements of 9.5{degrees}, which was compatible with results obtained in healthy subjects15,16,17. The simultaneous delivery of position information and somatotopic tactile feedback allowed both amputees to discriminate object size and compliance with high levels of accuracy (75.5%). These results demonstrate that touch information delivered via somatotopic neural stimulation and position information delivered via sensory substitution can be exploited simultaneously and efficiently by trans-radial amputees. This study paves the way towards more sophisticated bidirectional bionic limbs conveying rich, multimodal sensations.
- Citations
- 321
- FWCI
- 14.10
- Field percentile
- top 1%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Comparison of vibrotactile and joint-torque feedback in a myoelectric upper-limb prosthesis
- Proprioceptive Sonomyographic Control: A novel method of intuitive proportional control of multiple degrees of freedom for upper-extremity amputees
A. S. Dhawan, B. Mukherjee, … S. Sikdar·bioRxiv·Aug 20, 2018
- The crossmodal congruency task as a measure of intuitiveness of sensory feedback in the lower limb
Rohit Bose, Bailey A. Petersen, … Lee E. Fisher·bioRxiv·Aug 10, 2026
- Audible Feedback Improves Internal Model Strength and Performance of Myoelectric Prosthesis Control
A. W. Shehata, E. J. Scheme, J. W. Sensinger·bioRxiv·May 21, 2018
- Artificial Joint Speed Feedback for Myoelectric Prosthesis Control
Eric J. Earley, Reva E. Johnson, … Levi J. Hargrove·Scientific ReportsPeer-reviewed·Mar 4, 2021
- Neurostimulation Artifact Removal for Implantable Sensors Improves Signal Clarity and Decoding of Motor Volition
Eric J. Earley, Anton Berneving, … Max Ortiz-Catalan·Frontiers in Human NeurosciencePeer-reviewed·Oct 19, 2022