bioRxivNeurosciencePreprint
Characterising and Minimising Step and Filtering Artifacts in TMS-EEG Recordings
Marissa M. HoldeniD, Mitchell R. GoldsworthyiD, Wei‐Yeh LiaoiD, Scott R ClarkiD, Christopher C. ClineiD, Corey J. KelleriD, Julio Cesar Hernandez-PavoniD, Nigel C. RogaschiD
Abstract
Transcranial magnetic stimulation combined with electroencephalography (TMS-EEG) enables direct measurement of cortical reactivity via TMS-evoked potentials (TEPs). Interpretation of early TEP components however, is highly sensitive to stimulation and hardware-related artifacts. We identified and characterised a persistent, non-neural step-drift artifact unexpectedly present in recent TMS-EEG recordings from our group. We show that the artifact is distinct from previously described TMS pulse and discharge/decay artifacts and likely reflects a hardware interaction phenomenon. We demonstrated that amplifier settings, but not TMS pulse shape, substantially influenced artifact expression, with DC-coupled recordings with no online high-pass filter reducing step amplitude compared with AC-coupled recordings with a high-pass filter. Simulations additionally revealed that filtering over the step-drift artifact introduced pronounced ringing and edge artifacts, highlighting the need to address this artifact prior to data processing. We propose a processing pipeline incorporating robust polynomial detrending and a modified Butterworth filter with autoregressive extrapolation that minimised TEP distortion in both simulated and real data containing the step-drift artifact. Together, these findings provide practical recommendations for both preventing and correcting step-drift artifacts and underscore the need for formal definition and routine recognition of this artifact to improve reproducibility and data quality in TMS-EEG research.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- The effect of EEG lead configuration on early TMS-EEG artifacts
Kaisu Lankinen, Gabriel Fadel, … Tommi Raij·bioRxiv·Feb 12, 2026
- The impact of artifact removal approaches on TMS-EEG signal
Giacomo Bertazzoli, Romina Esposito, … Marta Bortoletto·NeuroImagePeer-reviewed·Jun 16, 2021
- A Practical Preprocessing Pipeline for Concurrent TMS-iEEG: Critical Steps and Methodological Considerations
Zhuoran Li, Xianqing Liu, … Jing Jiang·NeuroImagePeer-reviewed·Dec 24, 2025
- The rt-TEP tool: real-time visualization of TMS-Evoked Potential to maximize cortical activation and minimize artifacts
Silvia Casarotto, Matteo Fecchio, … Marcello Massimini·Journal of Neuroscience MethodsPeer-reviewed·Jan 21, 2022
- Designing and comparing cleaning pipelines for TMS-EEG data: a theoretical overview and practical example
Nigel C. Rogasch, Mana Biabani, Tuomas P. Mutanen·Journal of Neuroscience MethodsPeer-reviewed·Feb 7, 2022
- Improving the quality of combined EEG-TMS neural recordings: Introducing the Coil Spacer
Kathy L. Ruddy, Daniel Graham Woolley, … Nicole Wenderoth·Journal of Neuroscience MethodsPeer-reviewed·Nov 6, 2017