The effect of EEG lead configuration on early TMS-EEG artifacts
Kaisu LankineniD, Gabriel Fadel, Aapo R. NummenmaaiD, Risto Juhani IlmoniemiiD, Tommi RaijiD
Abstract
Transcranial magnetic stimulation (TMS) combined with electroencephalography (EEG) has strong potential for recording cortical reactivity and connectivity. However, this promise is hampered by TMS-induced EEG artifacts. Here, we examine the origins of these artifacts with phantom TMS-EEG recordings and simulations. We focus on two major types of artifacts: (1) the TMS pulse artifact during each [~]0.2 ms TMS pulse and (2) the decay artifact that may last tens of milliseconds. We examine how these artifacts change as a function of the relative position between TMS coil windings and EEG electrode leads. We also examine the hypothesis that certain EEG lead configurations may reduce or even cancel out these artifacts. In experimental results across 23 different TMS coil / EEG lead configurations, the amplitudes between the TMS pulse artifact and the decay artifact were highly correlated (Spearman {rho} = 0.86, p < 0.001), suggesting that the decay artifact is caused by the TMS pulse artifact. As predicted, in certain EEG lead configurations, both the TMS pulse and decay artifacts were minimized. The simulations confirmed that the TMS pulse artifacts depended on the electromagnetic induction from the TMS coil windings to the EEG leads. These results illuminate the generator mechanisms of--and possible means to reduce--both artifacts.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Characterising and Minimising Step and Filtering Artifacts in TMS-EEG Recordings
Marissa M. Holden, Mitchell R. Goldsworthy, … Nigel C. Rogasch·bioRxiv·May 18, 2026
- Improving the quality of combined EEG-TMS neural recordings: Introducing the Coil Spacer
Kathy L. Ruddy, Daniel Graham Woolley, … Nicole Wenderoth·Journal of Neuroscience MethodsPeer-reviewed·Nov 6, 2017
- The impact of artifact removal approaches on TMS-EEG signal
Giacomo Bertazzoli, Romina Esposito, … Marta Bortoletto·NeuroImagePeer-reviewed·Jun 16, 2021
- High-frequency sampling rate reduces TMS-pulse artifact duration but not decay artifact: implications for immediate TMS-EEG responses
Antonietta Stango, Agnese Zazio, … Marta Bortoletto·bioRxiv·Mar 5, 2025
- Identifying site- and stimulation-specific TMS-evoked EEG potentials using a quantitative cosine similarity metric
Michael Freedberg, Jack A. Reeves, … Eric M. Wassermann·PLoS ONEPeer-reviewed·Jan 13, 2020
- The non-transcranial TMS-evoked potential is an inherent source of ambiguity in TMS-EEG studies
Virginia Conde, Leo Tomasevic, … Hartwig Roman Siebner·NeuroImagePeer-reviewed·Oct 20, 2018