Journal of Neuroscience MethodsNeurosciencePeer-reviewed journal article
Improving the quality of combined EEG-TMS neural recordings: Introducing the Coil Spacer
Kathy L. RuddyiD, Daniel Graham Woolley, Dante MantiniiD, Joshua Henk BalstersiD, Nadja EnziD, Nicole WenderothiD
Abstract
BackgroundIn the last decade, interest in combined transcranial magnetic stimulation (TMS) and electroencephalography (EEG) approaches has grown substantially. Aside from the obvious artifacts induced by the magnetic pulses themselves, separate and more sinister signal disturbances arise as a result of contact between the TMS coil and EEG electrodes.\n\nNew methodHere we profile the characteristics of these artifacts and introduce a simple device - the coil spacer - to provide a platform allowing physical separation between the coil and electrodes during stimulation.\n\nResultsEEG data revealed high amplitude signal disturbances when the TMS coil was in direct contact with the EEG electrodes, well within the physiological range of viable EEG signals. The largest artifacts were located in the Delta and Theta frequency range, and standard data cleanup using independent components analysis (ICA) was ineffective due to the artifacts similarity to real brain oscillations.\n\nComparison with Existing MethodWhile the current best practice is to use a large coil holding apparatus to fixate the coil hovering over the head with an air gap, the spacer provides a simpler solution that ensures this distance is kept constant throughout testing.\n\nConclusionsThe results strongly suggest that data collected from combined TMS-EEG studies with the coil in direct contact with the EEG cap are polluted with low frequency artifacts that are indiscernible from physiological brain signals. The coil spacer provides a cheap and simple solution to this problem and is recommended for use in future simultaneous TMS-EEG recordings.
- Citations
- 19
- FWCI
- 1.09
- Field percentile
- top 23%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- The effect of EEG lead configuration on early TMS-EEG artifacts
Kaisu Lankinen, Gabriel Fadel, … Tommi Raij·bioRxiv·Feb 12, 2026
- Characterising and Minimising Step and Filtering Artifacts in TMS-EEG Recordings
Marissa M. Holden, Mitchell R. Goldsworthy, … Nigel C. Rogasch·bioRxiv·May 18, 2026
- Designing and comparing cleaning pipelines for TMS-EEG data: a theoretical overview and practical example
Nigel C. Rogasch, Mana Biabani, Tuomas P. Mutanen·Journal of Neuroscience MethodsPeer-reviewed·Feb 7, 2022
- The non-transcranial TMS-evoked potential is an inherent source of ambiguity in TMS-EEG studies
Virginia Conde, Leo Tomasevic, … Hartwig Roman Siebner·NeuroImagePeer-reviewed·Oct 20, 2018
- A Practical Preprocessing Pipeline for Concurrent TMS-iEEG: Critical Steps and Methodological Considerations
Zhuoran Li, Xianqing Liu, … Jing Jiang·NeuroImagePeer-reviewed·Dec 24, 2025
- EPI distortion correction for simultaneous human brain stimulation and imaging at 3T
Hyuntaek Oh, Jung Hwan Kim, Jeffrey M. Yau·Journal of Neuroscience MethodsPeer-reviewed·Aug 18, 2019