Correcting artifacts in ratiometric biosensor imaging; an improved approach for dividing noisy signals
Abstract
The accuracy of biosensor ratio imaging is limited by signal/noise. Signals can be weak when biosensor concentrations must be limited to avoid cell perturbation. This can be especially problematic in imaging of low volume regions, e.g., along the cell edge. The cell edge is an important imaging target in studies of cell motility. We show how the division of fluorescence intensities with low signal-to-noise at the cell edge creates specific artifacts due to background subtraction and division by small numbers, and that simply improving the accuracy of background subtraction cannot address these issues. We propose a new approach where, rather than simply subtracting background from the numerator and denominator, we subtract a noise correction factor (NCF) from the numerator only. This NCF can be derived from the analysis of noise distribution in the background near the cell edge or from ratio measurements in the cell regions where signal-to-noise is high. We test the performance of the method first by examining two noninteracting fluorophores distributed evenly in cells. This generated a uniform ratio that could provide a ground truth. We then analyzed actual protein activities reported by a single chain biosensor for the guanine exchange factor Asef, and a dual chain biosensor for the GTPase Cdc42. The reduction of edge artifacts revealed persistent Asef activity in a narrow band ([~]640 nm wide) immediately adjacent to the cell edge. For Cdc42, the NCF method revealed an artefact that would have been obscured by traditional background subtraction approaches.
- assay: fluorescence / live-cell microscopy
- research focus: cell signaling & trafficking
- approach: statistical model
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Calibration of FRET-based biosensors using multiplexed biosensor barcoding
Jhen-Wei Wu, Ming Wei Yang, … Chuan‐Hsiang Huang·iSciencePeer-reviewed·Oct 11, 2025
- Absolute measurement of cellular activities using photochromic single-fluorophore biosensors
V. Gielen, V. Mönkemöller, … P. Dedecker·bioRxiv·Oct 29, 2020
- Matryoshka: Ratiometric biosensors from a nested 1 cassette of green- and orange-emitting fluorescent proteins
C. Ast, J. Foret, … W. Frommer·bioRxiv·Jun 6, 2017
- Quantitative imaging of calcium dynamics with a green fluorescent biosensor and fluorescence lifetime imaging
Andrea Caldarola, Sebastián Palacios Martínez, Joachim Goedhart·Methods in molecular biologyPeer-reviewed·Oct 29, 2026
- RESTORE: Robust intEnSiTy nORmalization mEthod for Multiplexed Imaging
Young Hwan Chang, Koei Chin, … Joe W. Gray·Communications BiologyPeer-reviewed·Mar 9, 2020
- PIE-FLIM measurements of two different FRET-based biosensor activities in the same living cells
R. N. Day, C. A. Reissaus, … F. Pavalko·bioRxiv·Jan 10, 2020