bioRxivBioengineeringPreprint
SmartSpacer: Design, Implementation, and In-Vitro Validation of a Multimodal Sensorized Knee Spacer for Continuous Infection Monitoring in Two-Stage Revision Arthroplasty
Paul Morandell, Christoph Dillitzer, Nguyen Bach Tran, Vincent LallingeriD, Igor LaziciD, Rainer BurgkartiD, Oliver HaydeniD
Abstract
Periprosthetic joint infection (PJI) is the leading cause of failure in two-stage revision total knee arthroplasty (TKA). The timing of reimplantation currently relies on subjective clinical assessment, as no established method enables continuous, objective, local monitoring of infection dynamics during the spacer interval. We present the SmartSpacer, a sensorized antibiotic-loaded PMMA knee spacer integrating a miniaturized PCB within the tibial component (65 x 45 x 12 mm). The system incorporates digital temperature sensors, a CMOS camera module, a spectrometer, an inertial measurement unit, and a Bluetooth Low Energy (BLE) 5.2 transceiver. Firmware was developed on Zephyr RTOS with aggressive power management. Validation experiments covered power consumption profiling, BLE signal transmission through air, phantom liquid, and ex-vivo porcine knee tissue, temperature accuracy against a calibrated PT100 reference, and motion detection in seven healthy volunteers across three activity protocols. Firmware optimization reduced quiescent current from 700-850 {micro}A to 8 {micro}A, projecting a battery life exceeding 600 days at a clinically relevant sampling rate of one image and one spectrum per hour -- more than an order of magnitude beyond the maximum spacer implantation duration. BLE connectivity was maintained reliably up to 6 m through tissue-equivalent phantom liquid and up to 8-9 m in open air. Temperature sensors achieved {+/-}0.16 {degrees}C steady-state accuracy with self-heating artefacts below 0.15 {degrees}C. Motion detection scaled proportionally with activity intensity, though inter-subject variability in crutch-walking indicated that patient-specific calibration will be required. The SmartSpacer introduces an in vivo wearable - a temporary, implantable knee spacer providing continuous, wireless, multiparametric monitoring within the joint space. It has the potential to transform two-stage revision arthroplasty from empirically timed to data-driven, individualized clinical decision-making.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Towards In Vivo Wearable Diagnostics in Orthopaedics: Sensorized Bone Cement for Knee Spacer Applications
Nguyen Bach Tran, Laura Capogrosso, … Oliver Hayden·bioRxiv·Apr 23, 2026
- Measuring Clinically Relevant Knee Motions With A Self-Calibrated Wearable Sensor
T. J. Hullfish, F. Qu, … J. R. Baxter·bioRxiv·May 10, 2018
- Aptamer-Targeted PLGA Nanoparticles for Biofilm-Directed Intra-articular Antibiotic Delivery in Prosthetic Joint Infection
Zahra Eskandari, Yingfang Fan, … Ebru Oral·bioRxiv·Oct 27, 2026
- Conformable and robust force sensors to enable precision joint replacement surgery
L. Ives, A. Pace, … S. Kar-Narayan·bioRxiv·Aug 19, 2021
- Combination antibiotic delivery in PMMA provides sustained broad-spectrum antimicrobial activity and allows for post-implantation refilling
E. L. Cyphert, C.-y. Lu, … H. A. von Recum·bioRxiv·Nov 6, 2019
- A SENSORIZED 3D-PRINTED KNEE TEST RIG FOR EXPERIMENTAL VALIDATION OF PATELLAR TRACKING AND CONTACT SIMULATION AFTER TOTAL KNEE REPLACEMENT