bioRxivBioengineeringPreprint
Towards In Vivo Wearable Diagnostics in Orthopaedics: Sensorized Bone Cement for Knee Spacer Applications
Nguyen Bach Tran, Laura Capogrosso, Christoph Dillitzer, Paul Morandell, Vincent LallingeriD, Stephan Heller, Rainer BurgkartiD, Igor LaziciD, Oliver HaydeniD
Abstract
Periprosthetic joint infection (PJI) is a severe complication of total knee arthroplasty and is a leading cause of revision surgery, and is associated with significant morbidity. Two-stage exchange using antibiotic-loaded polymethylmethacrylate (PMMA) spacers remains the clinical gold standard, yet the decision to reimplant relies largely on indirect markers and clinical judgment, as no method allows continuous in situ assessment of infection resolution. Here, we report a sensorized knee spacer that transforms PMMA bone cement from a passive structural material into an active, wearable diagnostic device. A miniaturized multimodal sensor unit integrating optoelectronic and physicochemical sensing was embedded within the tibial spacer component and wirelessly coupled, enabling energy-efficient, 24/7 in vivo monitoring during the spacer interval for several months. We developed a reproducible encapsulation and integration strategy compatible with clinically realistic spatial, thermal, and mechanical constraints, without altering the established surgical workflow. The functionality of the embedded camera, spectrometer, and temperature sensors following cement integration was verified. Mechanical integrity and signal stability were confirmed under ISO-compliant dynamic biomechanical loading conditions. In vivo validation of the implantable wearable was preclinically demonstrated in a porcine model using human knee spacer dimensions. These findings establish the technical feasibility of sensor-integrated PMMA spacers and introduce bone cement as an enabling platform for smart orthopedic implants. Continuous, local monitoring of the peri-implant environment may open new pathways for evidence-based decision-making in infection management with temporary implantable wearables.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- SmartSpacer: Design, Implementation, and In-Vitro Validation of a Multimodal Sensorized Knee Spacer for Continuous Infection Monitoring in Two-Stage Revision Arthroplasty
Paul Morandell, Christoph Dillitzer, … Oliver Hayden·bioRxiv·Apr 29, 2026
- Combination antibiotic delivery in PMMA provides sustained broad-spectrum antimicrobial activity and allows for post-implantation refilling
E. L. Cyphert, C.-y. Lu, … H. A. von Recum·bioRxiv·Nov 6, 2019
- Smart bone plates can monitor fracture healing
M. C. Lin, D. Hu, … M. M. Maharbiz·bioRxiv·Jul 10, 2018
- The Effects of Vancomycin on the Viability and Osteogenic Potential of Bone-derived Mesenchymal Stem Cells
E. Booysen, H. Sadie-Van Gijsen, … L. M. Dicks·bioRxiv·May 8, 2018
- Glycolytic reprogramming underlies immune cell activation by polyethylene wear particles
C. V. Maduka, O. M. Habeeb, … C. H. Contag·bioRxiv·Oct 14, 2022
- Aptamer-Targeted PLGA Nanoparticles for Biofilm-Directed Intra-articular Antibiotic Delivery in Prosthetic Joint Infection
Zahra Eskandari, Yingfang Fan, … Ebru Oral·bioRxiv·Oct 27, 2026