bioRxivNeurosciencePreprint
Long-term mitigation of the foreign-body response with dexamethasone-eluting cochlear implants in mice
Aditya AlluriiD, Bryce HungeriD, md Fahad Hossain, Shakila Mahmuda FatimaiD, Muhammad Taifur RahmaniD, Brian J. MostaertiD, Robert D. GayiD, Ya Lang EnkeiD, Marlan Rex HanseniD, Alexander D. ClausseniD
Abstract
The inflammatory foreign body response that follows cochlear implantation produces intracochlear fibrosis, neo-ossification, and elevated electrode impedances that can compromise implant performance. Dexamethasone-eluting cochlear implants reduce this response, but the durability of their anti-inflammatory effect over long implantation intervals has not been established. Using a murine model of chronic cochlear implantation in CX3CR1+/eGFP Thy1+/eYFP dual-reporter mice, we compared dexamethasone-eluting and standard mouse cochlear implants at 224 and 336 days post-implantation. Density of CX3CR1+ macrophages, MHCII+CX3CR1+ antigen-presenting macrophages, -SMA+ fibrosis, and neo-ossification were quantified in the scala tympani, Rosenthal canal, and lateral wall of the basal turn. Standard implants produced persistent macrophage and antigen-presenting macrophage infiltration, accompanied by an -SMA+ fibrotic response and neo-ossification. Dexamethasone-eluting implants suppressed macrophage infiltration in all three regions out to 336 days and reduced fibrosis at 224 days. In the subset of cochleae with electrode array translocation, dexamethasone-eluting implants attenuated macrophage infiltration and confined the fibrotic and osseous response to the site of translocation, whereas standard implants produced a widespread response. A reduction in immune cell density was also observed in the contralateral, unimplanted cochleae of animals implanted with dexamethasone-eluting implants, suggesting a wider component to the drug's effect. Dexamethasone-eluting cochlear implants therefore provide sustained, long-term suppression of the cochlear foreign body response in mice, supporting their continued translation toward clinical application. This effect was associated with continued low-level dexamethasone elution out to 336 days post-implantation; further work is needed to assess the durability of this effect at the conclusion of drug elution.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Chronic Cochlear Implantation with and without Electric Stimulation in a Mouse Model Induces Robust Cochlear Influx of CX3CR1+/GFP Macrophages.
Alexander D. Claussen, René Vielman Quevedo, … Marlan Rex Hansen·Hearing ResearchPeer-reviewed·Apr 25, 2022
- Cochlear implant material effects on inflammatory cell function and foreign body response
M. J. Jensen, A. D. Claussen, … M. R. Hansen·bioRxiv·Jun 20, 2022
- Establishment of a cochlear lymphatic vascular network and immune surveillance system following cochlear implantation
Muhammad Taifur Rahman, Ibrahim Razu, … Marlan Rex Hansen·bioRxiv·Oct 26, 2026
- Reducing the foreign body response on human cochlear implants and their materials in vivo with photografted zwitterionic hydrogel coatings
R. R. Horne, N. Ben-Shlomo, … M. R. Hansen·bioRxiv·Nov 28, 2022
- A novel pyridoindole improves the recovery of residual hearing following cochlear implantation after a single preoperative application
Michael Nieratschker, Erdem Yıldız, … Hans Rommelspacher·bioRxiv·Feb 14, 2024
- Selonsertib-Eluting Electrode Coating Attenuates Cochlear Injury Pathways
Jacqueline M. Ogier, Lilith M. Caballero Aguilar, … Bryony A. Nayagam·bioRxiv·Apr 6, 2026