bioRxivBioengineeringPreprint
On the Reliability of Chronically Implanted Thin-Film Electrodes in Human Arm Nerves for Neuroprosthetic Applications
P. Cvancara, G. Valle, M. Mueller, T. Guiho, A. Hiairrassary, F. Petrini, S. Raspopovic, I. Strauss, G. Granata, E. Fernandez, P. M. Rossini, M. Barbaro, K. Yoshida, W. Jensen, J.-L. Divoux, D. Guiraud, S. Micera, T. Stieglitz
Abstract
Direct stimulation of peripheral nerves can successfully provide sensory feedback to amputees while using hand prostheses. Recent clinical studies have addressed this important limitation of current prostheses solutions using different implantable electrode concepts. Longevity of the electrodes is key to success. We have improved the long-term stability of the polyimide-based transverse intrafascicular multichannel electrode (TIME) that showed promising performance in clinical trials by integration of silicon carbide adhesion layers. The TIMEs were implanted in the median and ulnar nerves of three trans-radial amputees for up to six months. Here, we present the characterization of the electrical properties of the thin-film metallization as well as material status post explantationem for the first time. The TIMEs showed reliable performance in terms of eliciting sensation and stayed within the electrochemical safe limits maintaining a good working range with respect to amplitude modulation. After termination of the trials and explantation of the probes, no signs of corrosion or morphological change to the thin-film metallization was observed by means of electrochemical and optical analysis. Damage to the metallization was assigned exclusively to mechanical impacts during explantation and handling. The results indicate that thin-film metallization on polymer substrates is applicable in permanent implant system.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Stability of Thin-Film Metallization in Flexible Stimulation Electrodes: Analysis and Improvement of in vivo Performance
P. Cvancara, T. Boretius, … T. Stieglitz·bioRxiv·May 22, 2019
- All-polymeric transient neural probe for prolonged in-vivo electrophysiological recordings
L. Ferlauto, P. Vagni, … D. Ghezzi·bioRxiv·Mar 9, 2021
- Advances in Thin-Film Graphene Neurotechnology for Chronic Nerve Stimulation and Recording
Nicola Ria, Bruno Rodríguez‐Meana, … Jose Antonio Garrido·bioRxiv·Jan 26, 2026
- Long-Term Performance of Utah Slanted Electrode Arrays and Intramuscular Electromyographic Leads Implanted Chronically in Human Arm Nerves and Muscles
Jacob A. George, David M. Page, … Gregory A. Clark·Journal of Neural EngineeringPeer-reviewed·Oct 12, 2020
- Graphene-based thin film microelectrode technology for in vivo high resolution neural recording and stimulation
D. Viana, S. T. Walston, … J. A. Garrido·bioRxiv·Nov 16, 2022
- Ultraconformable cuff implants for long-term bidirectional interfacing of peripheral nerves at sub-nerve resolutions
Alejandro Carnicer‐Lombarte, Alexander J. Boys, … George G. Malliaras·Nature CommunicationsPeer-reviewed·Aug 30, 2024