Journal of Neural EngineeringNeurosciencePeer-reviewed journal article
Long-Term Performance of Utah Slanted Electrode Arrays and Intramuscular Electromyographic Leads Implanted Chronically in Human Arm Nerves and Muscles
Jacob A. GeorgeiD, David M. PageiD, Tyler S. DavisiD, Christopher C. DuncaniD, Douglas T. HutchinsoniD, Loren W. RiethiD, Gregory A. ClarkiD
Abstract
ObjectiveWe explore the long-term performance and stability of seven percutanous Utah Slanted Electrode Arrays (USEAs) and intramuscular recording leads (iEMGs) implanted chronically in the residual arm nerves and muscles of three human amputees as a means to permanently restore sensorimotor function after upper-limb. ApproachWe quantify the number of functional recording and functional stimulating electrodes over time. We also calculate the signal-to-noise ratio of USEA and iEMG recordings and quantify the stimulation amplitude necessary to evoke detectable sensory percepts. Furthermore, we quantify the consistency of the sensory modality, receptive field location, and receptive field size of USEA-evoked percepts. Main ResultsIn the most recent subject, involving USEAs with technical improvements, neural recordings persisted for 502 days (entire implant duration) and the number of functional recording electrodes for one USEA increased over time. However, for six out of seven USEAs the number of functional recording electrodes decreased within the first two months after implantation. The signal-to-noise ratio of neural recordings and electromyographic recordings stayed relatively consistent over time. Sensory percepts were consistently evoked over the span of 14 months, were not significantly different in size, and highlighted the nerves fascicular organization. The percentage of percepts with consistent modality or consistent receptive field location between sessions (~1 month apart) varied between 0-86.2% and 9.1-100%, respectively. Stimulation thresholds and electrode impedances increased initially but then remained relatively stable over time. SignificanceThis work demonstrates improved performance of USEAs, and provides a basis for comparing the longevity and stability of USEAs to that of other neural interfaces. Although USEAs provide a rich repertoire of neural recordings and sensory percepts, performance still generally declines over time. Future work should leverage the results presented here to further improve USEA design or to develop adaptive algorithms that can maintain a high level of performance.
- organism: human
- assay: electronic health records
- research focus: benchmarking
- approach: experimental assay
- Citations
- 75
- FWCI
- 4.58
- Field percentile
- top 4%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- On the Reliability of Chronically Implanted Thin-Film Electrodes in Human Arm Nerves for Neuroprosthetic Applications
P. Cvancara, G. Valle, … T. Stieglitz·bioRxiv·May 29, 2019
- Material Damage to Multielectrode Arrays after Electrolytic Lesioning is in the Noise
Alice Tor, Stephen E Clarke, … Paul Nuyujukian·bioRxiv·Mar 26, 2025
- Finite element model predicts micromotion-induced strain profiles that correlate with the functional performance of Utah arrays in humans and non-human primates
Adam M. Forrest, Nicolas G. Kunigk, … Takashi D.Y. Kozai·Journal of Neural EngineeringPeer-reviewed·Nov 5, 2025
- Utah Array Characterization and Histological Analysis of a Multi-Year Implant in Non-Human Primate Motor and Sensory Cortices
P. R. Patel, E. J. Welle, … C. A. Chestek·bioRxiv·Aug 27, 2022
- Planar Amorphous Silicon Carbide Microelectrode Arrays for Chronic Recording in Rat Motor Cortex
J. R. Abbott, E. N. Jeakle, … S. F. Cogan·bioRxiv·Nov 2, 2023
- Stability of Thin-Film Metallization in Flexible Stimulation Electrodes: Analysis and Improvement of in vivo Performance
P. Cvancara, T. Boretius, … T. Stieglitz·bioRxiv·May 22, 2019