henhaobio
Sign in

F1000ResearchGeneticsPeer-reviewed journal article

Accurate Cytogenetic Biodosimetry Through Automation Of Dicentric Chromosome Curation And Metaphase Cell Selection

Jin LiuiD, Yanxin LiiD, Ruth C. WilkinsiD, Farrah N. Flegal, Joan H.M. KnolliD, Peter K. RoganiD

PDFDOIPreprint

Abstract

Software to automate digital pathology relies on image quality and the rates of false positive and negative objects in these images. Cytogenetic biodosimetry detects dicentric chromosomes (DCs) that arise from exposure to ionizing radiation, and determines radiation dose received from the frequency of DCs. We present image segmentation methods to rank high quality cytogenetic images and eliminate suboptimal metaphase cell data based on novel quality measures. Improvements in DC recognition increase the accuracy of dose estimates, by reducing false positive (FP) DC detection. A set of chromosome morphology segmentation methods selectively filtered out false DCs, arising primarily from extended prometaphase chromosomes, sister chromatid separation and chromosome fragmentation. This reduced FPs by 55% and was highly specific to the abnormal structures ([≥]97.7%). Additional procedures were then developed to fully automate image review, resulting in 6 image-level filters that, when combined, selectively remove images with consistently unparsable or incorrectly segmented chromosome morphologies. Overall, these filters can eliminate half of the FPs detected by manual image review. Optimal image selection and FP DCs are minimized by combining multiple feature based segmentation filters and a novel image sorting procedure based on the known distribution of chromosome lengths. Applying the same segmentation filtering procedures to both calibration and test sample image data reduced the average dose estimation error from 0.4Gy to <0.2Gy, obviating the need to first manually review these images. This reliable and scalable solution enables batch processing multiple samples of unknown dose, and meets current requirements for triage radiation biodosimetry of high quality metaphase cell preparations.

Citations
32
FWCI
2.52
Field percentile
top 11%

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.

Similarity Map
SelectedSame fieldCross-field
THISShirley '20Li '16Rogan '21Canadell '19Subasinghe '16Deschemps '23
74% semantic matchGenetics
Ben C. Shirley, Joan H.M. Knoll, Jayne Moquet+5 more·International Journal of Radiation Biology·Sep 10, 2020· 16 citations