Aortic annuloplasty FSI digital twin of 3D-printed phantoms with 4D-flow MRI comparison
Luca BontempiiD, Marta ZattoniiD, Anna RamellaiD, Francesco MigliavaccaiD, Steffen RinggaardiD, Won Yong KimiD, Peter JohanseniD, Monika ColomboiD
Abstract
BackgroundAortic annuloplasty, involving the implantation of an external ring around the aortic root to reduce annular dimensions, is a promising treatment for aortic valve insufficiency. However, its hemodynamic effects remain underexplored due to the absence of computational models validated by experimental and clinical data. MethodsThis study introduces a computational fluid-structure interaction (FSI) model of supra valvular aortic annuloplasty using 4D-flow magnetic resonance imaging (MRI). Native and post-annuloplasty conditions of idealized aortic root phantoms, including the aortic valve, were CAD-modelled and 3D-printed with elastic resin. These phantoms were tested in a mock circulatory flow-loop providing normal pulsatile physiologic conditions using a glycerol-water mixture to simulate blood viscosity. Flow and pressure data collected from sensors were used as boundary conditions for FSI simulations. Experimental velocity fields from 4D-flow MRI were compared to computational results to assess model accuracy. ResultsMRI scans of the annuloplasty model showed an increased peak systolic velocity (up to 145.4 cm/s) and localized flow alterations, corresponding to a higher pressure gradient across the valve. During regurgitation, the annuloplasty model showed broader velocity distributions compared to the native condition. The FSI simulations closely matched 4D-flow MRI data, with strong correlation coefficients (r > 0.93) and minimal Bland-Altman differences, particularly during systolic phases. ConclusionsThis study establishes an integrative methodology combining in-vitro, in-silico, and clinical imaging techniques to evaluate aortic annuloplasty hemodynamics. The validated digital twin framework offers a pathway for patient-specific modelling, enabling prediction of surgical outcomes and optimization of aortic valve repair strategies.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 4
- FWCI
- 2.78
- Field percentile
- top 9%
- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- A novel MRI-based data fusion methodology for efficient, personalised, compliant simulations of aortic haemodynamics
C. Stokes, M. Bonfanti, … V. Diaz·bioRxiv·May 15, 2021
- Hemodynamic Analysis of a Repaired Ascending Aorta with Preserved Aortic Root
Hannah Zhai, Yurui Chen, … Vijay Vedula·Annals of Biomedical EngineeringPeer-reviewed·Oct 27, 2026
- Hemodynamics in Patients with Aortic Coarctation: A Comparison of in vivo 4D-Flow MRI and FSI Simulation
P. J. Nair, M. R. Pfaller, … A. L. Marsden·bioRxiv·Feb 13, 2023
- Aneurysmal Growth in Type-B Aortic Dissection: Assessing the Impact of Patient-Specific Inlet Conditions on Key Haemodynamic Indices
- Multi-modal Phantom Experiments, mimicking Flow through the Mitral Heart Valve
Lea Christierson, Petter Frieberg, … Nina Hakacova·Cardiovascular Engineering and TechnologyPeer-reviewed·May 23, 2024
- Fluid-Structure Interactions of Peripheral Arteries Using a Coupled in silico and in vitro Approach
S. Schoenborn, T. Lorenz, … M. C. Allenby·bioRxiv·Apr 17, 2023