Hemodynamic Analysis of a Repaired Ascending Aorta with Preserved Aortic Root
Hannah Zhai, Yurui Chen, Yuichiro Kitada, Hiroo TakayamaiD, Vijay VedulaiD
Abstract
PurposeTo evaluate the hemodynamic impact of restoring a normal sino-tubular junction (STJ) following a novel Hegar dilator-based procedure in patients undergoing root-sparing ascending thoracic aortic aneurysm (ATAA) repair using computational modeling. MethodsWe retrospectively selected an ATAA patient who underwent pre- and postoperative gated computed tomography angiography (CTA). We developed a novel workflow to segment the lumen, thick-walled aorta, and aortic valve from CTA images for subsequent blood flow analysis using computational fluid dynamics (CFD) and fluid-structure interaction (FSI). Morphological and hemodynamic characteristics of the root were quantified and compared against those of a control subject, with no noted ascending aortic dilation. The models sensitivity to graft properties and leaflet material heterogeneity was analyzed. ResultsBoth CFD and FSI results showed that the postoperative geometry reconstructed with a normal STJ profile reintroduces sinus vortices during peak systole, similar to the control subject, but were absent pre-surgery. Accounting for aortic valve leaflets in FSI studies yielded qualitatively similar results to the CFD cases, albeit with locally elevated velocities, time-averaged wall shear stress (TAWSS), and energy dissipation, likely due to the dynamically changing orifice area and differing profiles of the left ventricular outflow tract (LVOT). ConclusionWe demonstrated that the novel Hegar dilator-based STJ reconstruction restores normal blood flow patterns, highlighting the importance of reprofiling the aortic sinuses and STJ. The study also highlights the models sensitivities, particularly the LVOT shape and leaflet morphology and mobility, and may assist planning STJ reconstruction to yield optimal hemodynamics before intervention.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 1
- FWCI
- 4.70
- Field percentile
- top 10%
- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Aortic annuloplasty FSI digital twin of 3D-printed phantoms with 4D-flow MRI comparison
Luca Bontempi, Marta Zattoni, … Monika Colombo·Computers in Biology and MedicinePeer-reviewed·May 17, 2025
- Computational and Experimental Evaluation of a Flow-Conditioning Anastomotic Device for Arteriovenous Fistula Maturation
Keith Louis Saum, Begoña Campos, … Prabir Roy-Chaudhury·BioengineeringPeer-reviewed·Sep 19, 2026
- Computational analysis to assess hemodynamic forces in descending thoracic aortic aneurysms
Francesca Duca, Daniele Bissacco, … Christian Vergara·The Journal of PhysiologyPeer-reviewed·May 28, 2025
- Haemodynamic impact of implant materials and anastomotic angle in peripheral vascular grafts
Sabrina Schoenborn, Thomas Lloyd, … Mark C. Allenby·Biomechanics and Modeling in MechanobiologyPeer-reviewed·Jan 13, 2026
- A Study of Coronary Artery Disease in the Left Circumflex Artery via Artificial Vessel Restoration
F. Liu, A. Paulraj·bioRxiv·May 27, 2020
- Hemodynamic-Structural Multi-Fidelity Assessment of Endovascular Flow Diversion Strategies for Cerebral Aneurysm Treatment: An Integrated Computational and Experimental Framework
Dipu Roy, Farah Sadia Antara, … Jafrin Sultana·bioRxiv·Oct 19, 2026