Sign in
BioengineeringbioRxiv
Preprint

An Engineered Contact Lens for Passive and Sustained Release of Lifitegrast, an Anti-Dry Eye Syndrome Drug

C. Mu, V. Lee, Y. Liu, Y. Han, g. marriott

Abstract

Lifitegrast is an FDA-approved drug that inhibits T-cell mediated inflammation associated with dry eye syndrome (DES). Lifitegrast is a potent inhibitor of the interaction between LFA-1 on T-cells and ICAM-1 on endothelial cells at the ocular surface. While effective in treating DES, 5% (81.2 mM) lifitegrast has low drug utilization and elicits off-target effects. Here we engineer contact lenses to release therapeutically-relevant doses of lifitegrast to every tear film for up to 10-hours. Lifitegrast is coupled to the polymer of the soft hydrogel lens via a photolabile (caged) crosslinker. Exposures of the lens to the 400-430 nm wavelengths of indoor daylight excite the caged crosslinker molecules and trigger a bond-cleavage reaction that releases authentic lifitegrast passively to the tear film. The photoproduct of the reaction remains chemically-linked to the polymer of the single-use lens. Our studies show that passive exposures of the lens to indoor light would generate an average of 990 nM lifitegrast to every tear film in a zero-order reaction for up to 10-hours. This concentration exceeds the Kd for the interaction between ICAM-1 and LFA-1 by [~]330-fold and would sustain inhibition of inflammatory responses at the ocular surface. The amount of lifitegrast released from the lens increases during exposures to outdoor sunlight. Over a 10-hour exposure to indoor light, a single lens would release 0.44% of the lifitegrast present in two drops of commercial 5% lifitegrast. Compared to tear-drop approaches, our engineered lenses would sustain the passive delivery of therapeutically-relevant doses of lifitegrast over a longer period, and exhibit improved drug utilization at a lower cost. Our technology could easily be integrated into daily-use contact lenses in order to prevent inflammation at the ocular surface, dry-eye and contact lens-mediated discomfort. Graphical Abstract O_FIG O_LINKSMALLFIG WIDTH=198 HEIGHT=200 SRC="FIGDIR/small/439289v1_ufig1.gif" ALT="Figure 1"> View larger version (75K): org.highwire.dtl.DTLVardef@1049076org.highwire.dtl.DTLVardef@a83fceorg.highwire.dtl.DTLVardef@1f52c4borg.highwire.dtl.DTLVardef@12f0ead_HPS_FORMAT_FIGEXP M_FIG C_FIG

PDFDOI

02 /Specification & Classification

Click any tag to browse matching papers

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.