Development and Validation of Thalia: A High-ResolutionPediatric Computational Model of a 10-Month-Old Infant
Alice Albrecht, Georgios NtolkerasiD, Lilla ZölleiiD, Georgios A. Sideris, Francesca MarturanoiD, Michael Howard LeviD, Patricia Ellen GrantiD, Giorgio BonmassariD
Abstract
Numerical human models are essential to advance medical device design, safety assessment, and study how anatomical development influences physiological processes. Despite increasing availability of pediatric models, a critical gap remains in high-resolution, non-morphed whole-body models representing children around one year of age. Existing pediatric models are often derived from morphing older anatomies or lack sufficient tissue segmentation to accurately capture early developmental anatomy. This study introduces Thalia, a non-morphed, high-resolution numerical model of a healthy 10-month-old female. The model was constructed by segmenting 442 tissues from Magnetic Resonance Imaging data. Brain tissues were automatically segmented using an infant-specific FreeSurfer framework, followed by semi-automated and manual refinement in 3DSlicer. The model was validated by expert review and quantitative comparison with age-matched anatomical values reported in the literature. The resulting whole-body model provides detailed anatomical representation across the brain, musculoskeletal system, vasculature, and internal organs, enabling realistic assignment of tissue-specific properties for computational studies. It provides a versatile platform for pediatric medical device development, dosimetry, safety assessment, and bioelectromagnetic simulations. This pediatric numerical anatomical model is openly available as an open-source resource. HighlightsO_LIHigh-resolution model of a 10-month-old child developed from MRI data C_LIO_LI442 tissues segmented to capture early anatomical development accurately C_LIO_LIModel validated against expert review and age-matched anatomical data C_LIO_LIIllustrative Example of a pediatric transcranial magnetic stimulation use case C_LI
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- FWCI
- 0.00
- Field percentile
- 41th percentile
- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- PARS: an automated, open-source pipeline for subject-specific finite element head modelling from MRI
Vahid Darvishi, Emily Yik Kwan Chan, … Mazdak Ghajari·bioRxiv·Jul 6, 2026
- Head model personalization: A framework for morphing lifespan brain images and brains with substantial anatomical changes
X. Li·bioRxiv·Apr 10, 2021
- Developing a multi-modal neuroimaging-based BrainAge model across childhood
Shi Yu Chan, Pei Huang, … Ai Peng Tan·bioRxiv·May 19, 2026
- MiniMAP: An automatic pipeline for paediatric lower limb musculoskeletal model generation
Laura Carman, Timothy Salemink Waldren, … Julie Choisne·bioRxiv·Oct 31, 2026
- A High-Resolution Head and Brain Computer Model for Forward and Inverse EEG Simulation
Alexandra Warner, Jess Tate, … Christopher R. Johnson·bioRxiv·Feb 18, 2019
- Development and Validation of an MRI-Derived Head-Neck Finite Element Model
H. Bahreinizad, S. K. Chowdhury, … F. Santos·bioRxiv·Feb 12, 2023