bioRxivBioinformaticsPreprint
dnoise: Fast Native Data Reduction for Bruker timsTOF
Abstract
Bruker timsTOF acquisitions produce dense native .d files whose storage, transfer, and archival become substantial at high throughput. We present dnoise, an open-source Rust tool that removes points directly from timsTOF frames and writes a native-compatible .d directory. dnoise retains ions that form coherent streaks across the ion-mobility dimension and applies acquisition-aware gates to signal that cannot be selected for fragmentation. On a three-species benchmark spanning ddaPASEF and diaPASEF at 5- and 15-minute gradients, default MS1-only denoising reduced the frame binary by 35 to 53%. Label-free quantification accuracy was preserved in both modes. ddaPASEF peptide-spectrum-match, peptide, and protein-group counts were unchanged, as expected with the searched MS/MS spectra untouched, and diaPASEF precursor and protein-group counts changed only slightly. Every tested processing run completed in 69 seconds or less on the benchmark workstation. Optional MS/MS denoising produced greater reduction but sacrificed several percent of identifications. Thus, a substantial fraction of native timsTOF frame data can be removed with little analytical change.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Comparison of TIMS-PASEF quantitative proteomics data-analysis workflows using FragPipe, DIA-NN, and Spectronaut from a user's perspective
Alejandro Fernández-Vega, Federica Farabegoli, … Ignacio Ortea·bioRxiv·Nov 29, 2021
- Enhanced Identifications and Quantification through Retention Time Down-Sampling in Fast-Cycling diagonal-PASEF Methods
Christopher Below, Oliver M. Bernhardt, … Lukas Reiter·Molecular & Cellular ProteomicsPeer-reviewed·Dec 10, 2025
- Simplifying MS1 and MS2 spectra to achieve lower mass error, more dynamic range, and higher peptide identification confidence on the Bruker timsTOF Pro
Daryl Wilding‐McBride, Laura F. Dagley, … Andrew Ian Webb·PLoS ONEPeer-reviewed·Jul 7, 2022
- A de novo MS1 feature detector for the Bruker timsTOF Pro
Daryl Wilding‐McBride, Andrew Ian Webb·PLoS ONEPeer-reviewed·Nov 30, 2022
- AlphaTims: Indexing trapped ion mobility spectrometry - time of flight data for fast and easy accession and visualization
Sander Willems, Eugenia Voytik, … Matthias Mann·Molecular & Cellular ProteomicsPeer-reviewed·Jan 1, 2021
- DuReS: An R package for denoising experimental tandem mass spectrometry-based metabolomics data
Shayantan Banerjee, Prajval Nakrani, … Pramod P. Wangikar·Analytical ChemistryPeer-reviewed·Jun 6, 2025