Distinct Sources of a Bovine Blastocyst Digital Image do not Produce the Same Classification by a Previously Trained Software using Artificial Neural Network
Vitória Bertogna Guilherme, Micheli Pronunciate, Priscila Helena dos SantosiD, Diego de Souza Ciniciato, M TakahashiiD, José Celso RochaiD, Marcelo Fábio Gouveia NogueiraiD
Abstract
We develop an online graphical and intuitive interface connected to a server aiming to facilitate access to professionals worldwide that face problems with bovine blastocysts classification. The interface Blasto3Q (3Q is referred to the three qualities of the blastocyst grading) contains a description of 24 variables that are extracted from the image of the blastocyst and analyzed by three Artificial Neural Networks (ANNs) that classifies the same loaded image. The same embryo (i.e., the biological specimen) was submitted to digital image capture by the control group (inverted microscope with 40x of magnification) and to experimental group (stereomicroscope with maximum of magnification plus 4x zoom from the cell phone). The 36 images obtained from control and experimental groups were uploaded on the Blasto3Q. Each image from both sources was evaluated for segmentation and submitted (only if it could be properly or partially segmented) to the quality grade classification by the three ANNs of the Blasto3Q program. In the group control, all the images were properly segmented, whereas 38.9% (07/18) and 61.1% (11/18) of the images from the experimental group, respectively could not be segmented or were partially segmented. The percentage of agreement was calculated when the same blastocyst was evaluated by the same ANN from the two sources (control and experimental groups). On the 54 potential evaluations of the three ANNs (i.e., 18 images been evaluated by the three networks) from the experimental group only 22.2% agreed with evaluations of the control (12/54). Of the remaining 42 disagreed evaluations from experimental group, 21 were unable to be performed and 21 were wrongly processed when compared with control evaluation.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 1
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- deepBlastoid: A Deep Learning-Based High-Throughput Classifier for Human Blastoids Using Brightfield Images with Confidence Assessment
- Robust Automated Assessment of Human Blastocyst Quality using Deep Learning
Pegah Khosravi, Ehsan Mohamad Kazemi, … Iman Hajirasouliha·bioRxiv·Aug 20, 2018
- A Dataset for Deep Learning based Cleavage-stage Blastocyst Prediction with Time-lapse Images
Sijia Wang, Jing Fan, … David Yiu Leung Chan·bioRxiv·Dec 26, 2023
- Harnessing cytoplasmic particles movement of the human early embryo analysed by advanced imaging and artificial intelligence to predict development to blastocyst stage
Giovanni Coticchio, Giulia Fiorentino, … Maurizio Zuccotti·Reproductive BioMedicine OnlinePeer-reviewed·Dec 24, 2020
- Morphologic Classification and Automatic Diagnosis of Bacterial Vaginosisby Deep Neural Networks
- Automatic Ploidy Prediction and Quality Assessment of Human Blastocyst Using Time-Lapse Imaging
Suraj Rajendran, Matthew Brendel, … Iman Hajirasouliha·Nature CommunicationsPeer-reviewed·Sep 5, 2024