bioRxivBiophysicsPreprint
Bi-Phasic Quasistatic Brain Communication for Fully Untethered Connected Brain Implants
Abstract
Wireless communication using electro-magnetic (EM) fields acts as the backbone for information exchange among wearable devices around the human body. However, for Implanted devices, EM fields incur high amount of absorption in the tissue, while alternative modes of transmission including ultrasound, optical and magnetoelectric methods result in large amount of transduction losses due to conversion of one form of energy to another, thereby increasing the overall end-to-end energy loss. To solve the challenge of wireless powering and communication in a brain implant with low end-end channel loss, we present Bi-Phasic Quasistatic Brain Communication (BP-QBC), achieving < 60dB worst-case end-to-end channel loss at a channel length of ~55mm, by using Electro-quasistatic (EQS) Signaling that avoids transduction losses due to no field-modality conversion. BP-QBC utilizes dipole coupling based signal transmission within the brain tissue using differential excitation in the transmitter (TX) and differential signal pick-up at the receiver (RX), while offering ~41X lower power w.r.t. traditional Galvanic Human Body Communication (G-HBC) at a carrier frequency of 1MHz, by blocking any DC current paths through the brain tissue. Since the electrical signal transfer through the human tissue is electro-quasistatic up to several 10s of MHz range, BP-QBC allows a scalable (bps-10Mbps) duty-cycled uplink (UL) from the implant to an external wearable. The power consumption in the BP-QBC TX is only 0.52 W at 1Mbps (with 1% duty cycling), which is within the range of harvested power in the downlink (DL) from a wearable hub to an implant through the EQS brain channel, with externally applied electric currents < 1/5th of ICNIRP safety limits. Furthermore, BP-QBC eliminates the need for sub-cranial interrogators/repeaters, as it offers better signal strength due to no field transduction. Such low end-to-end channel loss with high data rates enabled by a completely new modality of brain communication and powering has deep societal and scientific impact in the fields of neurobiological research, brain-machine interfaces, electroceuticals and connected healthcare.
- organism: human
- assay: electrophysiology
- research focus: drug response / drug discovery
- research focus: benchmarking
- approach: experimental assay
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- On the Interaction of Biopotential Sensing and Right Leg Drive System with Electro-Quasistatic Human Body Communication
S. Sriram, K. Polachan, S. Sen·bioRxiv·Jun 13, 2022
- Stable, chronic in-vivo recordings from a fully wireless subdural-contained 65,536-electrode brain-computer interface device
Tae‐Sung Jung, Nanyu Zeng, … Kenneth L. Shepard·Nature ElectronicsPeer-reviewed·Dec 8, 2025
- In-The-Wild Interference Characterization andModelling for Electro-Quasistatic-HBC withMiniaturized Wearables
S. Sen, P. Mehrotra, … S. Weigand·bioRxiv·Nov 6, 2020
- Understanding The Role of Magnetic and Magneto-Quasistatic Fields in Human Body Communication
M. Nath, A. K. Ulvog, … S. Sen·bioRxiv·Oct 30, 2020
- A low-power communication scheme for wireless, 1000 channel brain-machine interfaces
J. T. Costello, S. R. Nason, … C. A. Chestek·bioRxiv·Mar 11, 2022
- A Wirelessly Powered Implantable CMOS Neural Recording Sensor Array using Pulse-based Neural Amplifier
G. Mulberry, K. A. White, B. N. Kim·bioRxiv·Oct 17, 2019