NeuroImageNeurosciencePeer-reviewed journal article
Mouth magnetoencephalography: A unique perspective on the human hippocampus
Tim M. TierneyiD, Andrew D LevyiD, Daniel N. BarryiD, Sofie S. MeyeriD, Yoshihito ShigiharaiD, Matt Everatt, Stephanie MelloriD, José David LópeziD, Sven BestmanniD, Niall HolmesiD, Gillian RobertsiD, Ryan M. HilliD, Elena BotoiD, James LeggettiD, Vishal ShahiD, Matthew J. BrookesiD, Richard W BowtelliD, Eleanor A. MaguireiD, Gareth Robert BarnesiD
Abstract
Traditional magnetoencephalographic (MEG) brain imaging scanners consist of a rigid sensor array surrounding the head; this means that they are maximally sensitive to superficial brain structures. New technology based on optical pumping means that we can now consider more flexible and creative sensor placement. Here we explored the magnetic fields generated by a model of the human hippocampus not only across scalp but also at the roof of the mouth. We found that simulated hippocampal sources gave rise to dipolar field patterns with one scalp surface field extremum at the temporal lobe and a corresponding maximum or minimum at the roof of the mouth. We then constructed a fitted dental mould to accommodate an Optically Pumped Magnetometer (OPM). We collected data using a previously validated hippocampal-dependent task to test the empirical utility of a mouth-based sensor, with an accompanying array of left and right temporal lobe OPMs. We found that the mouth sensor showed the greatest task-related theta power change. We also found that, as predicted by the simulations, the mouth sensor was anti-correlated with those on over the temporal lobes. We found that this sensor had a mild effect on the reconstructed power in the hippocampus (~10% change) but that coherence images between the mouth sensor and reconstructed source images showed a global maximum in the right hippocampus. We conclude that augmenting a scalp-based MEG array with sensors in the mouth shows unique promise for both basic scientists and clinicians interested in interrogating the hippocampus.
- Citations
- 87
- FWCI
- 4.98
- Field percentile
- top 3%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Measuring MEG closer to the brain: Performance of on-scalp sensor arrays
Joonas Iivanainen, Matti Stenroos, Lauri T. Parkkonen·NeuroImagePeer-reviewed·Dec 19, 2016
- MRI-free OPM-MEG recovers medial temporal lobe theta during scene imagination
Conor Thornberry, Prathiksha Math, … Robert Whelan·bioRxiv·Aug 18, 2026
- Requirements for coregistration accuracy in on-scalp MEG
Rasmus Zetter, Joonas Iivanainen, … Lauri T. Parkkonen·Brain TopographyPeer-reviewed·Jun 22, 2018
- A Novel, Robust, and Portable Platform for Magnetoencephalography using Optically Pumped Magnetometers
Holly Schofield, Ryan M. Hill, … Matthew J. Brookes·Imaging NeurosciencePeer-reviewed·Jan 1, 2024
- Non-invasive tracking of hippocampal theta oscillations
Eleonora Marcantoni, Christoph Daube, … Simon Hanslmayr·bioRxiv·Jan 13, 2026
- Sensor localization using magnetic dipole-like coils: A method for highly accurate co-registration in on-scalp MEG
Christoph Pfeiffer, Silvia Ruffieux, … Justin F. Schneiderman·NeuroImagePeer-reviewed·Feb 28, 2020