Impact of an intra-abdominal cooling device during open kidney transplantation in pigs
A. Longchamp, R. P. H. Meier, N. Colucci, A. Balaphas, L. Orci, A. Nastasi, G. Longchamp, S. Moll, A. Klauser, M. Pascual, F. Lazeyras, J.-M. Corpataux, L. Bühler
Abstract
BackgroundKidney transplantation using deceased donors still suffers from high post-operative dysfunction rate. During implantation into the recipient, the kidney rewarms. This second warm ischemia time, which is not monitored, is harmful especially if prolonged. We recently developed an intra-abdominal cooling device that efficiently prevents kidney rewarming during robotic transplantation, and prevent ischemia-reperfusion injuries. Here, we tested the benefits of this cooling device during open kidney transplantation in pigs.\n\nMaterialsKidneys were procured from large pigs by open bilateral nephrectomy. Following procurement, kidneys were flushed with 4{degrees}C Institut Georges Lopez-1 preservation solution, and placed on ice for 128.5 {+/-} 23.2 min. The cooling device was used to continuously cool down the kidney during the vascular anastomosis time.\n\nMethodsAnimals underwent double sequential autologous open renal transplantation with (n = 7) and without (n = 6) intra-abdominal cooling. Renal cortex temperature and urine output were monitored. The severity of the ischemia reperfusion lesions was analyzed by histology (modified Goujon score).\n\nResultsMean anastomosis time was similar between groups (43.9 {+/-} 13 min). At reperfusion, the renal cortex temperature was lower in the group with cooling (4.3 {+/-} 1.1{degrees}C vs 26.5 {+/-} 5.5{degrees}C p <0.001). The cooled kidneys tended to be protected from injury, including some histopathological ischemia-reperfusion lesions. With the device, kidneys had a better immediate post-operative urine output (p=0.05).\n\nConclusionsOur results indicate that the intra-abdominal cooling device significantly reduces second warm ischemic time during transplantation, is technically safe, and does not prolong anastomotic time.
02 /Specification & Classification
Click any tag to browse matching papers- Organism
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Developing a safe 15-hour preservation protocol of donor kidneys using normothermic machine perfusion
- Comparative analysis of kidney transplantation modeled using precision-cut kidney slices and kidney transplantation in pigs
Matthias B. Moor, Johan Nordström, … Hannes Olauson·bioRxiv·Jan 17, 2024
- Antioxidant Polysulfide Nanoparticles Ameliorate Ischemia-Reperfusion Injury and Improve Porcine Kidney Function Post-Transplantation
John P. Stone, Richard d’Arcy, … James E. Fildes·bioRxiv·Jun 21, 2023
- Functional recovery of vitrified and nanowarmed human-scale pig kidneys
韩宗虎 Han Zonghu, Bat‐Erdene Namsrai, … Erik B. Finger·bioRxiv·Oct 14, 2026
- End of preservation normothermic machine perfusion of porcine kidneys after ischaemic injury reprograms metabolism and induces fibrosis after transplant despite unchanged function: insights from the renal proteome.
John F. Mulvey, Corinna Snashall, … Sadr ul Shaheed·bioRxiv·Sep 27, 2024
- Advancing multi-day ex vivo kidney perfusion using spatially resolved metabolomics
M. J. A. de Haan, F. M. R. Witjas, … T. J. Rabelink·bioRxiv·May 10, 2023