Establishing the Validity of Compressed Sensing Diffusion Spectrum Imaging
Hamsanandini RadhakrishnaniD, Chenying ZhaoiD, Valerie J. SydnoriD, Erica B. BalleriD, Philip A. CookiD, Damien A. FairiD, Barry GiesbrechtiD, Bart LarseniD, Kristin A. MurthaiD, David R. RoalfiD, Sage Rush‐Goebel, Russell Taki ShinoharaiD, Haochang ShouiD, Matthew Dylan TisdalliD, Jean M. VetteliD, Scott T. GraftoniD, Matthew CieslakiD, Theodore Daniel SatterthwaiteiD
Abstract
Diffusion Spectrum Imaging (DSI) using dense Cartesian sampling of q-space has been shown to provide important advantages for modeling complex white matter architecture. However, its adoption has been limited by the lengthy acquisition time required. Sparser sampling of q-space combined with compressed sensing (CS) reconstruction techniques has been proposed as a way to reduce the scan time of DSI acquisitions. However prior studies have mainly evaluated CS-DSI in post-mortem or non-human data. At present, the capacity for CS-DSI to provide accurate and reliable measures of white matter anatomy and microstructure in the living human brain remains unclear. We evaluated the accuracy and inter-scan reliability of 6 different CS-DSI schemes that provided up to 80% reductions in scan time compared to a full DSI scheme. We capitalized on a dataset of twenty-six participants who were scanned over eight independent sessions using a full DSI scheme. From this full DSI scheme, we subsampled images to create a range of CS-DSI images. This allowed us to compare the accuracy and inter-scan reliability of derived measures of white matter structure (bundle segmentation, voxel-wise scalar maps) produced by the CS-DSI and the full DSI schemes. We found that CS-DSI estimates of both bundle segmentations and voxel-wise scalars were nearly as accurate and reliable as those generated by the full DSI scheme. Moreover, we found that the accuracy and reliability of CS-DSI was higher in white matter bundles that were more reliably segmented by the full DSI scheme. As a final step, we replicated the accuracy of CS-DSI in a prospectively acquired dataset (n=20, scanned once). Together, these results illustrate the utility of CS-DSI for reliably delineating in vivo white matter architecture in a fraction of the scan time, underscoring its promise for both clinical and research applications.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 3
- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- High-fidelity approximation of grid- and shell-based sampling schemes from undersampled DSI using compressed sensing: Post mortem validation
Robert J. Jones, Chiara Maffei, … Anastasia Yendiki·NeuroImagePeer-reviewed·Sep 27, 2021
- Deep Learning Initialized Compressed Sensing (Deli-CS) in Volumetric Spatio-Temporal Subspace Reconstruction
Siddharth Iyer, Sophie Schauman, … Kawin Setsompop·bioRxiv·Mar 28, 2023
- Benchmarking Orientation Distribution Function Estimation Methods for Tractometry in Single-Shell Diffusion Magnetic Resonance Imaging - An Evaluation of Test-Retest Reliability and Predictive Capability
Amelie Rauland, Steven L. Meisler, … Theodore Daniel Satterthwaite·bioRxiv·Sep 2, 2025
- Evaluation of Kernel Low-Rank Compressed Sensing in preclinical Diffusion Magnetic Resonance Imaging
Diego Alves Rodrigues de Souza, Hervé Mathieu, … Emmanuel Barbier·Frontiers in NeurosciencePeer-reviewed·Jun 2, 2023
- Test-retest reliability and long-term stability of 3-tissue constrained spherical deconvolution methods for analyzing diffusion MRI data
Benjamin T. Newman, Thijs Dhollander, … T. Jason Druzgal·Magnetic Resonance in MedicinePeer-reviewed·Feb 28, 2020
- In vivo human whole-brain Connectom diffusion MRI dataset at 760 μm isotropic resolution
Fuyixue Wang, Zijing Dong, … Kawin Setsompop·Scientific DataPeer-reviewed·Apr 29, 2021