Pre-equilibrium biosensors: A new approach towards rapid and continuous molecular measurements
Abstract
Almost all biosensors that use ligand-receptor binding operate under equilibrium conditions. However, at low ligand concentrations, the equilibration with the receptor (e.g., antibodies and aptamers) become slow and thus equilibrium-based biosensors are inherently limited in making measurements that are both rapid and sensitive. In this work, we provide a theoretical foundation for a novel method through which biosensors can quantitatively measure ligand concentration before reaching equilibrium. Rather than only measuring receptor binding at a single time-point, the pre-equilibrium approach leverages the receptors kinetic response to instantaneously quantify the changing ligand concentration. Importantly, analyzing the biosensor output in frequency domain, rather than in the time domain, we show the degree to which noise in the biosensor affects the accuracy of the pre-equilibrium approach. Through this analysis, we provide the conditions under which the signal-to-noise ratio of the biosensor can be maximized for a given target concentration range and rate of change. As a model, we apply our theoretical analysis to continuous insulin measurement and show that with a properly selected antibody, the pre-equilibrium approach could make the continuous tracking of physiological insulin fluctuations possible.
02 /Specification & Classification
Click any tag to browse matching papers- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Continuous detection of glucose and insulin in live animals
M. Poudineh, C. L. Maikawa, … H. T. Soh·bioRxiv·Jan 22, 2020
- Physical limit to concentration sensing in a changing environment
T. Mora, I. Nemenman·bioRxiv·Aug 14, 2019
- An Antibody-Based Molecular Switch for Continuous Biosensing
I. A. P. Thompson, J. Saunders, … H. T. Soh·bioRxiv·Mar 7, 2023
- The SensorOverlord predicts the accuracy of measurements with ratiometric biosensors
J. A. Stanley, S. B. Johnsen, J. Apfeld·bioRxiv·Jan 31, 2020
- GEQO biosensors for absolute analyte quantification in single cells
Sascha M. Kuhn, Elisa Nerli, … André Nadler·bioRxiv·May 5, 2025
- Surface Transmon Resonance (STR): a handheld nanogap biosensor for real-time, label-free molecular binding kinetics
Bryan Karekin Chantigian, Sang‐Hyun Oh·npj BiosensingPeer-reviewed·Feb 19, 2026