bioRxivNeurosciencePreprint
A 7-channel high-Tc SQUID-based on-scalp MEG system
Christoph PfeifferiD, Silvia RuffieuxiD, Lars Jönsson, M. L. Chukharkin, Alexei KalaboukhoviD, Minshu XieiD, Dag WinkleriD, Justin F. SchneidermaniD
Abstract
Due to their higher operating temperature, high-Tc superconducting quantum interference devices (SQUIDs) require less thermal insulation than the low-Tc sensors that are utilized in commercial magnetoen-cephalography (MEG) systems. As a result, they can be placed closer to the head, where neuromagnetic fields are higher and more focal, potentially leading to higher spatial resolution. The first such on-scalp MEG measurements using high-Tc SQUIDs have shown the potential of the technology. In order to be useful for neuroscience and clinical applications, however, multi-channel systems are required. Herein, we present a 7-channel on-scalp MEG system based on high-Tc SQUIDs. The YBCO SQUID magnetometers are arranged in a dense, head-aligned hexagonal array inside a single, liquid nitrogen-cooled cryostat. The spacing between the magnetometers and the head is adjustable down to 1 mm. The sensors are side-mounted on the cryostat that is mounted on an articulated armature for recordings on arbitrary head locations of a seated subject. We demonstrate white noise levels of 50-130 fT/Hz1/2 at 10 Hz, sensor-to-sensor crosstalk values of <0.6%, and single-fill operation times of 16 hours. We validate the system with MEG recordings of visual alpha modulation and auditory evoked fields. The system is thus useful for densely and sensitively sampling neuromagnetic fields over any[~] 10 cm2 patch of the scalp surface over the course of a day.
- Citations
- 8
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- On-scalp MEG SQUIDs are sensitive to early somatosensory activity unseen by conventional MEG
Lau M. Andersen, Christoph Pfeiffer, … Daniel Lundqvist·NeuroImagePeer-reviewed·Jul 10, 2020
- On-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers
Joonas Iivanainen, Rasmus Zetter, … Lauri T. Parkkonen·NeuroImagePeer-reviewed·Mar 15, 2019
- Signal-to-noise ratio of event-related fields in on-scalp and off-scalp MEG
Mainak Jas, Teppei Matsubara, … Seppo P. Ahlfors·bioRxiv·Aug 21, 2026
- Sensor localization using magnetic dipole-like coils: A method for highly accurate co-registration in on-scalp MEG
Christoph Pfeiffer, Silvia Ruffieux, … Justin F. Schneiderman·NeuroImagePeer-reviewed·Feb 28, 2020
- Measuring MEG closer to the brain: Performance of on-scalp sensor arrays
Joonas Iivanainen, Matti Stenroos, Lauri T. Parkkonen·NeuroImagePeer-reviewed·Dec 19, 2016
- Detection of the 40-Hz Auditory Steady-state Response with Optically Pumped Magnetometers
Kyung‐min An, Jeong Hyun Shim, … Kiwoong Kim·Scientific ReportsPeer-reviewed·Oct 26, 2022