Sign in
BioengineeringAnnals of Biomedical Engineering
Peer-reviewed journal article

Switching the left and the right hearts: A novel bi-ventricle mechanical support strategy with spared native single-ventricle

E. Sisli, K. Pekkan, C. Yildirim, I. B. Aka, O. N. Tuncer, Y. Atay, M. Ozbaran

Abstract

Mechanical circulatory support (MCS) is used as a bridge-to-heart transplantation for end-stage failing Fontan patients with single-ventricle (SV) circulation. Donor shortage and complexity of the single-ventricle circulation physiology demands novel circulatory support systems and alternative solutions. An out-of-the-box circulation concept in which the left and right ventricles are switched with each other inspired a novel bi-ventricle MCS configuration for the "failing" Fontan patients. In the proposed configuration, the systemic circulation is maintained by a conventional mechanical ventricle assist device while the venous circulation is delegated to the native SV. This approach spares the SV and puts it to a new use at the right-side providing the most needed venous flow pulsatility. To analyze its feasibility and performance, 8 realistic Fontan circulation scenarios have been studied via a multi-compartmental lumped parameter cardiovascular model (LPM). Model is developed specifically for simulating the SV circulation and validated against pulsatile mock-up flow loop measurements for the ideal (Fontan), failed (VD) and assisted Fontan (PVR-cmcs) scenarios. The proposed surgical configuration maintained the cardiac index (3-3.5 l/min/m2) providing a normal mean systemic arterial pressure. For a failed SV with low ejection fraction (EF=26%), representing a typical systemic failure, proposed configuration introduced a venous/pulmonary pulsatility of [~]28 mmHg and a drop of 2 mmHg in central venous pressure (CVP) with acceptable pulmonary artery pressures (17.5 mmHg). In the pulmonary vascular resistance (PVR) failure model, it provided approximately 5 mmHg drop in CVP with venous/pulmonary pulsatility reaching [~]22 mmHg. For high PVR failure case with a healthy SV (EF = 44%) pulmonary hypertension is likely to occur, indicating a need for precise functional assessment of the failed-ventricle before it is considered for the proposed arrangement. Comprehensive in vitro and in silico results encourage this concept as an economical alternative to the conventional bi-ventricle MCS pending animal experiments.

02 /Specification & Classification

Click any tag to browse matching papers

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.

Similarity Map
SelectedSame fieldCross-field
THISEmuna '26Gruenwald '20Wan '24Brown '26Nakashima '23Murtada '23
66% semantic matchBioengineering
Nir Emuna, Zinan Hu, Alison Lesley Marsden+1 more·npj Regenerative Medicine·Jan 15, 2026· 2 citations