Frontiers in Cellular and Infection MicrobiologyMolecular BiologyPeer-reviewed journal article
Multiple Cross Displacement Amplification Coupled with Gold Nanoparticles-Based Lateral Flow Biosensor for Detection of the Mobilized Colistin Resistance Gene mcr-1
Lin GongiD, Ernan Liu, Jie CheiD, Juan LiiD, Xiaoli LiuiD, Huiqiong Xu, Jiansheng LiangiD
Abstract
Fast dissemination of the mobilized colistin resistance (mcr) gene mcr-1 in Enterobacteriaceae causes a huge threat to the treatment of severe infection. In the current report, a multiple cross displacement amplification (MCDA) coupled with the detection of amplified products by gold nanoparticles-based lateral flow biosensor (LFB) assay (MCDA-LFB) was established to identify the mcr-1 gene with simpleness, rapidity, specificity and sensitivity. The MCDA-LFB assay was performed at a isothermal temperature (63{degrees}C) for only 30 min during the amplification stage, and the reaction products were directly identified by using LFB which obtained the result with 2 min. The entire process of experiments, from templates extraction to result judging, was accomplished less than 60 min. For the analytical specificity of this method, all of the 16 mcr-1-producing strains were positive, and all of the non-mcr-1 isolates got the negative results. The sensitivity of mcr-1-MCDA-LFB assay was as little as 600 fg of plasmid DNA per reaction in pure culture, and approximately 4.5x103 CFU/mL (~4.5 CFU/reaction) in fecal samples spiked with 100 l of strains. Therefore, this technique established in the present study is suitable for the surveillance of mcr-1 gene in clinic and livestock industry.
- Citations
- 25
- FWCI
- 1.58
- Field percentile
- top 19%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- The global distribution and spread of the mobilized colistin resistance gene mcr-1
R. Wang, L. van Dorp, … F. Balloux·bioRxiv·Nov 17, 2017
- A Portable Fluorescence Platform for Decentralized One-Health mcr-1 Monitoring
Maryhory Vargas-Reyes, Roberto Alcántara, … Pohl Milón·bioRxiv·Jul 27, 2026
- Fast and robust detection of colistin resistance in Escherichia coli using the MALDI Biotyper Sirius mass spectrometry system
R. C. Furniss, L. Dortet, … G. Larrouy-Maumus·bioRxiv·Aug 30, 2019
- The fitness landscape of the mobilized colistin resistance gene mcr-1
Z. Guo, S. Feng, … J.-R. Yang·bioRxiv·Jul 21, 2022
- A Novel Plasmid-Encoded Mobile Colistin Resistance Gene mcr-13.1 Detected in Escherichia coli Isolated from Grassland.
Marwa Alawi, Thị Thùy, … Fiona Walsh·bioRxiv·Jul 21, 2026
- Inducible colistin resistance via a disrupted plasmid-borne mcr-1 gene in a 2008 Vietnamese Shigella sonnei isolate
Duy Pham Thanh, Ha Thanh Tuyen, … Kathryn E Holt·Journal of Antimicrobial ChemotherapyPeer-reviewed·May 30, 2016